Status
Comment
Login
Code 3901496
Name PROVOR_III Profiling Float
Description Argo UK Bio
Project remOcean
Uk-Bioargo
Institution Met Office (Ocean Weather Services)
Data Assembly Center BO : BODC
Activity Active
Status
Comment
First station date 20/10/2014 17:05:00
Last station date 12/06/2021 13:35:00
Float cycles 370, 369, 368, 367, 366, 365, 364, 363, 362, 361, 360, 359, 358, 357, 356, 355, 354, 353, 352, 351, 350, 349, 348, 347, 346, 345, 344, 343, 342, 341, 340, 339, 338, 337, 336, 335, 334, 333, 332, 331, 330, 329, 328, 327, 326, 325, 324, 323, 322, 321, 320, 319, 318, 317, 316, 315, 314, 313, 312, 311, 310, 309, 308, 307, 306, 305, 304, 303, 302, 301, 300, 299, 298, 297, 296, 295, 294, 293, 292, 291, 290, 289, 288, 287, 286, 285, 284, 283, 282, 281, 280, 279, 278, 277, 276, 275, 274, 273, 272, 271, 270, 269, 268, 267, 266, 265, 264, 263, 262, 261, 260, 259, 258, 257, 256, 255, 254, 253, 252, 251, 250, 249, 248, 247, 246, 245, 244, 243, 242, 241, 240, 239, 238, 237, 236, 235, 234, 233, 232, 231, 230, 229, 228, 227, 226, 225, 224, 223, 222, 221, 220, 219, 218, 217, 216, 215, 214, 213, 212, 211, 210, 209, 208, 207, 206, 205, 204, 203, 202, 201, 200, 199, 198, 197, 196, 195, 194, 193, 192, 191, 190, 189, 188, 187, 186, 185, 184, 183, 182, 181, 180, 179, 178, 177, 176, 175, 174, 173, 172, 171, 170, 169, 168, 167, 166, 165, 164, 163, 162, 161, 160, 159, 158, 157, 156, 155, 154, 153, 152, 151, 150, 149, 148, 147, 146, 145, 144, 143, 142, 141, 140, 139, 138, 137, 136, 135, 134, 133, 132, 131, 130, 129, 128, 127, 126, 125, 124, 123, 122, 121, 120, 119, 118, 117, 116, 115, 114, 113, 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 3901496
(C) Coriolis data centre - 2021.06.13
T/S Diagram
Section chart


Overlayed profiles


Waterfall profiles


Configuration
Profiler TYPE PROVOR
Profiler VERSION 6.01
Profiler CRC TYPE 16
Profiler LAUNCH DATETIME 20/10/2014 15:02:00
Profiler LAUNCH LATITUDE -22.32
Profiler LAUNCH LONGITUDE -25.06
Profiler PROBE CODE 836
Profiler EXPERIMENT ID Uk-Bioargo
Profiler EXPERIMENT ID remOcean
Profiler CONDUCTIVITY ACCURACY 2
Platform activity flag A
The last valid station id of the platform 77684331
Data centre in charge of platform data processing BO
Positioning system GPS
Transmission identifier (ARGOS, ORBCOMM, etc.) metbio007d
The telecommunications system used IRIDIUM
Model of the float SAT_STG__OC_metbio007d
The name of the manufacturer NKE
Instrument type OIN14EN-S4-05
Direction of the profiles B
Name of the principal investigator Giorgio Dall'Olmo
Quality on launch date, time and location 1
Quality on start date 1
Identifier of the deployment platform RRS James Clark Ross
Name of the cruise AMT24
Date of last update of the metadata of the platform 29/06/2017 20:00:00
Date of last update of the trajectory of the platform 12/06/2021 16:33:03
Version number of the data handbook 1.2
List of parameters with real-time calibration information PSAL
Calibration equation for this parameter PSAL_ADJUSTED = a1 * PSAL + a0
Calibration coefficients for this equation a1=1, a0=0.0000
Comment applying to this parameter calibration Real-time salinity adjustment
Date of the calibration 20200722000000
Firmware version 1.08
Data centre executive in charge of platform data processing IF
The configuration of battery packs in the float 4DD LI
The type of controller board I535
The secondary type of controller board CAMAT256
The serial number of the primary controller board C128040146
The serial number of the secondary controller board I1349005
The float owner Uk-Bioargo
The operating institution of the float PML_Plymouth
Anderaa calibration coeff C0 0.00277723
Anderaa calibration coeff C1 0.000118884
Anderaa calibration coeff C2 0.00000230032
Anderaa calibration coeff C3 230.564
Anderaa calibration coeff C4 -0.335537
Anderaa calibration coeff C5 -55.7473
Anderaa calibration coeff C6 4.56537
Anderaa optode phase coeff 0 0
Anderaa optode phase coeff 1 1
Anderaa optode phase coeff 2 0
Anderaa optode phase coeff 3 0
Aanderaa Optode temp coeff 0 23.7177
Aanderaa Optode temp coeff 1 -0.0306956
Aanderaa Optode temp coeff 2 0.00000284249
Aanderaa Optode temp coeff 3 -0.00000000416135
Aanderaa Optode temp coeff 4 0
Aanderaa Optode temp coeff 5 0
Category of instrument FLOAT
Number of the SIM card 8988169234000608190
Number of the bluetooth connection 2013 07 146
Comment on float visual inspection done just before deployment OK
Startup date of the float 20/10/2014 15:02:00
Angle of Beta measurements (in angular degree) 124
Wavelength of ECO Beta #<DIM_LEVEL> measurements (in nanometer) 532
Wavelength of ECO Beta #<DIM_LEVEL> measurements (in nanometer) 700
Wavelength of ECO sensor for emission of CHLA fluorescence measurements (in nanometer) 695
Wavelength of ECO sensor for excitation of CHLA fluorescence measurements (in nanometer) 470
Vertical pressure offset due to the fact that the ECO sensor is not exactly at the CTD pressure (in dbar) 0.1
Bandwidth of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 10
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 380
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 412
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 490
Vertical pressure offset due to the fact that the OCR sensor is not exactly at the CTD pressure (in dbar) -0.08
Vertical pressure offset due to the fact that the OPTODE sensor is not exactly at the CTD pressure (in dbar) 0
State of the vector board show mode (0: OFF; 1: ON) 0
State of the sensor board show mode (0: OFF; 1: ON) 0
Platform type PROVOR_III
Type of sensor from L22 SeaVox Device Catalogue TOOL0669
Type of sensor from L22 SeaVox Device Catalogue TOOL0826
Optode is set up to perform measurements in air for calibration (yes/no) no
Delay between CTD and Optode (in second) 0
New DARK value is provided (in pool or in lab) (yes/no) yes
Date of last update of the tech data of the platform 12/06/2021 16:42:05
Configuration phases
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES SBE SBE41CP 5675
CTD_TEMP SBE SBE41CP 5675
CTD_CNDC SBE SBE41CP 5675
OPTODE_DOXY AANDERAA AANDERAA_OPTODE_4330 1536
RADIOMETER_DOWN_IRR380 SATLANTIC SATLANTIC_OCR504_ICSW 40314
RADIOMETER_DOWN_IRR412 SATLANTIC SATLANTIC_OCR504_ICSW 40314
RADIOMETER_DOWN_IRR490 SATLANTIC SATLANTIC_OCR504_ICSW 40314
RADIOMETER_PAR SATLANTIC SATLANTIC_OCR504_ICSW 40314
FLUOROMETER_CHLA WETLABS ECO_FLBB2 3440
BACKSCATTERINGMETER_BBP700 WETLABS ECO_FLBB2 3440
BACKSCATTERINGMETER_BBP532 WETLABS ECO_FLBB2 3440
Physical parameters
Name Units Accuracy Resolution
CTD_PRES decibar 2.4 1
CTD_TEMP degree_Celsius 0.002 0.001
CTD_CNDC psu 0.005 0.001
OPTODE_DOXY degree
OPTODE_DOXY degree
OPTODE_DOXY degree_Celsius
OPTODE_DOXY micromole/kg 10% 0.001
RADIOMETER_DOWN_IRR380 count
RADIOMETER_DOWN_IRR412 count
RADIOMETER_DOWN_IRR490 count
RADIOMETER_PAR count
RADIOMETER_DOWN_IRR380 W/m^2/nm
RADIOMETER_DOWN_IRR412 W/m^2/nm
RADIOMETER_DOWN_IRR490 W/m^2/nm
RADIOMETER_PAR microMoleQuanta/m^2/sec
FLUOROMETER_CHLA count
BACKSCATTERINGMETER_BBP700 count
BACKSCATTERINGMETER_BBP532 count
FLUOROMETER_CHLA mg/m3
BACKSCATTERINGMETER_BBP700 m-1
BACKSCATTERINGMETER_BBP532 m-1
Calibrations
Parameter Equation Coefficients Comment
PRES
TEMP
PSAL
C1PHASE_DOXY
C2PHASE_DOXY
TEMP_DOXY
DOXY
PPOX_DOXY
RAW_DOWNWELLING_IRRADIANCE380
RAW_DOWNWELLING_IRRADIANCE412
RAW_DOWNWELLING_IRRADIANCE490
RAW_DOWNWELLING_PAR
DOWN_IRRADIANCE380
DOWN_IRRADIANCE412
DOWN_IRRADIANCE490
DOWNWELLING_PAR
FLUORESCENCE_CHLA
BETA_BACKSCATTERING700
BETA_BACKSCATTERING532
CHLA
BBP700
BBP532
Technical parameters Details