Code 3902127
Name ARVOR DEEP Profiling Float
Description ARGO AtlantOS
Project AtlantOS
Institution Euro-Argo
Data Assembly Center IF : CORIOLIS
Activity Active
Status
Comment
First station date 25/08/2018 14:52:00
Last station date 12/06/2021 11:49:40
Float cycles 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 3902127
(C) Coriolis data centre - 2021.06.18
T/S Diagram
Section chart

Overlayed profiles

Waterfall profiles

Configuration
Profiler TYPE PROVOR
Profiler VERSION 5.64
Profiler CRC TYPE 16
Profiler CYCLE PERIOD 10
Profiler IMMERSION DRIFT PERIOD 720
Profiler LAUNCH DATETIME 25/08/2018 13:07:00
Profiler LAUNCH LATITUDE 43.0002
Profiler LAUNCH LONGITUDE -15.4009
Profiler REFERENCE DATETIME 27/08/2018 00:00:00
Profiler REFERENCE INTERNAL DATE 25075
Profiler PROBE CODE 838
Profiler EXPERIMENT ID AtlantOS
Profiler CONDUCTIVITY ACCURACY 2
Profiler PARKING DEPTH 2500
Profiler PROFILE DEPTH 3700
Platform activity flag A
The last valid station id of the platform 77684232
Bathy 4970
Profiler configuration - Reference day 2
Data centre in charge of platform data processing IF
Positioning system GPS
Positioning system IRIDIUM
Transmission identifier (ARGOS, ORBCOMM, etc.) 497342
The telecommunications system used IRIDIUM
Model of the float DEEP-ARVOR
The name of the manufacturer NKE
Instrument type AD1726-16FR102
Direction of the profiles B
Name of the principal investigator Pedro Velez
Quality on launch date, time and location 1
Date (UTC) of the first descent of the float. 25/08/2018 12:40:00
Quality on start date 1
Identifier of the deployment platform Ramon Margalef
Identifier of stations used to verify the first profile yes
The number of times this cycle repeats 1
Name of the cruise RADPROF0818
Date of last update of the metadata of the platform 30/08/2018 19:00:00
Date of last update of the trajectory of the platform 12/06/2021 14:33:13
Version number of the data handbook 1.2
Theoretical time of end of ascent to surface 12
Profiler configuration - Periode de transmission en fin de vie (minute) 60
Profiler configuration - Duree maxi d activation ev en surface (cs) 1800
Profiler configuration - Volume transfere par l ev maxi autorise en profondeur (cm3) 17
Profiler configuration - Duree maxi d activation pompe en profondeur (cs) 450
Profiler configuration - Duree maxi d activation pompe en remontee (cs) 1120
Profiler configuration - Dur?e nominale d activation pompe en emergence (cs) 28000
Profiler configuration - Tolerance sur l atteinte de la pression de consigne (dBar) 50
Profiler configuration - Pression maxi a ne pas depasser (dBar) 4220
Profiler configuration - Pression de debut de reduction de la duree d activation ev en surface (dBar) 1
Profiler configuration - Critere de pression de debut de plongee (dBar) 12
Profiler configuration - Nbre de positions hors tolerance autorise en derive conduisant a repositionnement 2
Profiler configuration - Mode de gestion de l echouage en descente a pression de derive 0
Profiler configuration - Critere d echouage: volume cumule (cm3) 47
Profiler configuration - Pression en dessous de laquelle le flotteur reste pose en attente profil remontee (dBar) 200
Profiler configuration - Diminution de la pression visee en cas d echouage (dBar) 100
Profiler configuration - Tolerance sur maintien de la pression de consigne (dBar) 50
Profiler configuration - Mode d acquisition de la mesure 1
Profiler configuration - Periode d alternance profil - si=1, pas d alternance (jour) 1
Profiler configuration - Profondeur de profil alterne (dBar) 4000
Profiler configuration - Vitesse moyenne descente (mm/s) 27
Profiler configuration - Increment de profondeur de consigne a chaque cycle (dBar) 0
Profiler configuration - Coefficient de calibrage pression A 1.367
Profiler configuration - Coefficient de calibrage pression B -203.62
List of parameters with real-time calibration information DOXY
Calibration equation for this parameter PPOX_DOXY_ADJUSTED = a1 * PPOX_DOXY + a0
Calibration coefficients for this equation a1=1.0716, a0=0.0000
Comment applying to this parameter calibration initial assessment by coriolis according to https://doi.org/10.13155/76709 based on case1_1 (cycles 2 3 4 5 6)
Date of the calibration 20180825130700
Firmware version 5608A11
The manual version for the float 33-16-028_UTI
A standard format number to describe the data format for each float 120003
The configuration of battery packs in the float 4DD LI
The type of controller board I535
The serial number of the primary controller board C147542-0015
The float owner Euro-Argo
The operating institution of the float Euro-Argo
Delay Before Mission 0
Period Descent Profile 0
Period Ascent Profile 10
INTERMEDIATE SURFACE THRESHOLD 10
Depth intermediate threshold 200
Surface Slice Thickness 1
Intermediate Slice Thickness 10
Depth Slice Thickness 25
PRES when the SBE pump is switched off 5
Anderaa calibration coeff C0 0.00279639
Anderaa calibration coeff C1 0.000118786
Anderaa calibration coeff C2 0.0000024315
Anderaa calibration coeff C3 231.226
Anderaa calibration coeff C4 -0.367252
Anderaa calibration coeff C5 -53.9131
Anderaa calibration coeff C6 4.57746
Average ascent speed 90
Anderaa optode phase coeff 0 -1.492
Anderaa optode phase coeff 1 1
Anderaa optode phase coeff 2 0
Anderaa optode phase coeff 3 0
CTD cut-off pressure 5
preset duration of the 'up' time (start of ascent to start of descent) 5.5
maximum cycles 500
Aanderaa Optode temp coeff 0 23.6627
Aanderaa Optode temp coeff 1 -0.0310529
Aanderaa Optode temp coeff 2 0.00000286346
Aanderaa Optode temp coeff 3 -0.00000000422942
Aanderaa Optode temp coeff 4 0
Aanderaa Optode temp coeff 5 0
Category of instrument FLOAT_DEEP
Id of the sail connector RADPROF201808
Number of the bluetooth connection 2016 06 0015
Firmware checksum 0F63
Comment on float visual inspection done just before deployment OK
Comment on ballast visual inspection done just before deployment OK
Startup date of the float 25/08/2018 12:40:00
Description of the float buoyancy just after deployment At pressure sensor
Name of the deployment operator Alberto Gonzales Santana
Method used to deploy the float ROPE
Comment on the float deployment Statiohn 134 CTD cast 031
Comment on float visual inspection done during acceptance tests OK
Comment on ballast visual inspection done during acceptance tests OK
Float firmware version during acceptance tests 5608A11
Float firmware checksum during acceptance tests 0F63
Float clock set at the beginning of the acceptance tests no
Float battery voltage measured at the beginning of the acceptance tests 14.3
Float internal vacuum measured with a full bladder at the beginning of the acceptance tests 770
Spy mode set to ON at the beginning of the acceptance tests OK
Show mode set to OFF at the beginning of the acceptance tests OK
Mission armed at the beginning of the acceptance tests OK
Startup date of the float for acceptance tests 26/12/2017 10:00:00
Drift of the float clock during acceptance tests N/A
Float battery voltage measure at the end of the acceptance tests 14.2
Float internal vacuum measured during the acceptance tests 775
Comment on internal vacuums measured during the acceptance tests -
General comments on the acceptance tests OK
Comment on float visual inspection done during the pre-deployment check OK
Comment on ballast visual inspection done during the pre-deployment check OK
Float clock set during the pre-deployment check OK
Float battery voltage measured during the pre-deployment check 14.2
Float internal vacuum measured during the pre-deployment check 795
Comment on internal vacuums measured during the acceptance tests -
Spy mode set to ON during the pre-deployment check OK
Show mode set to OFF during the pre-deployment check OK
Mission armed during the pre-deployment check OK
vector pressure sampling period during ascent 2
pression stab remontée 10
Vertical pressure offset due to the fact that the OPTODE sensor is not exactly at the CTD pressure (in dbar) -0.3
Platform type ARVOR_D
Time delay between each new attempt to descend when the float is stuck at the surface. 60
1 if the Optode is active during the cycle, 0 otherwise. 1
Threshold used by the float to stop ascent speed control and pump actions. 10
1 if the float transmits hydraulic data at the end of the cycle, 0 otherwise. 1
Period of the pressure checks during the float descent. 5
If the float vertical motion, is less than this threshold, the float makes buoyancy adjustments. 4
Maximum number of GPS location acquisition retries before it resets the GPS. 24
Delay before a second Iridium session performed by the float just before diving for a new cycle. 30
Type of sensor from L22 SeaVox Device Catalogue TOOL0669
Type of sensor from L22 SeaVox Device Catalogue TOOL0826
Comment on float internal checks before deployment (valve and pump actions, argos transmission check) OK
Float deployment height (m) 0
Ship speed during float deployment (kts) 0.1
Wind speed during float deplayment (Beaufort) 4
Sea state during float deployment (calm, smooth, slight, moderate, rough, very rough, high, very high, phenomenal) Slight (0.5 to 1.25 m)
Float clock value set during acceptance tests (dd/mm/yyyy hh:mm) ('!TI') 26/12/2017 09:29:00
PRES measurement done before acceptance deployment -8
TEMP measurement done before acceptance deployment 9.865
PSAL measurement done before acceptance deployment 8
Comment on float internal checks before acceptance deployment (valve and pump actions, argos transmission check) OK
Buoyancy description before acceptance deployment Water @ top of P sensor
Buoyancy description after acceptance deployment Water @ top of P sensor
PRES measurement done after acceptance deployment -1
TEMP measurement done after acceptance deployment 12.366
PSAL measurement done after acceptance deployment 6
Float firmware version at pre-deployment 5608A11
Float clock value set during pre-deployment (dd/mm/yyyy hh:mm) ('!TI') 25/08/2018 13:36:07
PRES measurement done during pre-deployment tests 0
TEMP measurement done during pre-deployment tests 21.422
PSAL measurement done during pre-deployment tests 10
Cycle periodicity of the 'in air measurement' phase. 1
Sampling period during the 'in air measurement' phase. 30
Duration of the 'in air measurement' phase. 5
Duration of the last pump action of the buoyancy acquisition phase when a 'in air measurement' phase is programmed (in centi-seconds). 38000
The float has an additonial stick for air measurement (yes/no) yes
Calibration adjusted error 10
Code (used by the decoder) of the method used to estimate adjustment error 1_1
Date of last update of the tech data of the platform 12/06/2021 16:36:50
Configuration phases
Total time of a cycle : descent + parking + ascent + surface Preset duration of the down time (start of descent to start of ascent) Preset duration of the up time (start of ascent to start of descent) Pressure of subsurface drifts Deepest pressure sampled in the ascending profile
240 2500 3700
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES KISTLER KISTLER_10153PSIA 4994351
CTD_TEMP SBE SBE41CP 8985
CTD_CNDC SBE SBE41CP 8985
OPTODE_DOXY AANDERAA AANDERAA_OPTODE_4330 2656
Physical parameters
Name Units Accuracy Resolution
CTD_PRES decibar 2.4 0.1
CTD_TEMP degC 0.002 0.001
CTD_CNDC psu 0.005 0.001
OPTODE_DOXY degree 0.002
OPTODE_DOXY degree 0.002
OPTODE_DOXY degree_Celsius 0.001
OPTODE_DOXY micromole/kg 8 umol/kg or 10% 1 umol/kg
OPTODE_DOXY millibar
Calibrations
Parameter Equation Coefficients Comment
PRES
TEMP
PSAL
C1PHASE_DOXY
C2PHASE_DOXY
TEMP_DOXY
DOXY
PPOX_DOXY
Technical parameters Details