Status
Comment
Login
Code 6901754
Name PROVOR CTS3-DO Profiling Float
Description Argo Coriolis - RREX
Project Euro-Argo
RREX
CORIOLIS
Institution IFREMER, Institut Français de Recherche pour l'Exploitation de la Mer
Data Assembly Center IF : CORIOLIS
Activity Active
Status
Comment
First station date 11/07/2016 04:20:00
Last station date 16/06/2021 23:43:00
Float cycles 181, 180, 179, 178, 177, 176, 175, 174, 173, 172, 171, 170, 169, 168, 167, 166, 165, 164, 163, 162, 161, 160, 159, 158, 157, 156, 155, 154, 153, 152, 151, 150, 149, 148, 147, 146, 145, 144, 143, 142, 141, 140, 139, 138, 137, 136, 135, 134, 133, 132, 131, 130, 129, 128, 127, 126, 125, 124, 123, 122, 121, 120, 119, 118, 117, 116, 115, 114, 113, 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 6901754
(C) Coriolis data centre - 2021.06.18
T/S Diagram
Section chart

Overlayed profiles

Waterfall profiles

Configuration
Profiler TYPE PROVOR
Profiler VERSION 4.42
Profiler CRC TYPE 16
Profiler CYCLE PERIOD 10
Profiler IMMERSION DRIFT PERIOD 720
Profiler LAUNCH DATETIME 10/07/2016 23:20:00
Profiler LAUNCH LATITUDE 59.1663
Profiler LAUNCH LONGITUDE -34.4745
Profiler REFERENCE DATETIME 11/07/2016 00:00:00
Profiler REFERENCE INTERNAL DATE 24298
Profiler PROBE CODE 841
Profiler EXPERIMENT ID CORIOLIS
Profiler EXPERIMENT ID Euro-Argo
Profiler EXPERIMENT ID RREX
Profiler CONDUCTIVITY ACCURACY 2
Profiler PARKING DEPTH 1000
Profiler PROFILE DEPTH 2000
Platform activity flag A
The last valid station id of the platform 77734032
Bathy 2505
Profiler configuration - Reference day 1
Data centre in charge of platform data processing IF
Positioning system ARGOS
Transmission identifier (ARGOS, ORBCOMM, etc.) 146740
The telecommunications system used ARGOS
The program identifier used by the transmission system 2412
The frequency of transmission from the float 401 653 000
The repetition rate of transmission from the float 40
Model of the float PROVOR-CTS3.1-DO
The name of the manufacturer NKE
Instrument type OIN-14DO-S31-05
Direction of the profiles B
Name of the principal investigator Virginie THIERRY
Quality on launch date, time and location 1
Date (UTC) of the first descent of the float. 11/07/2016 02:00:00
Quality on start date 1
Identifier of the deployment platform SARMIENTO DE GAMBOA
Identifier of stations used to verify the first profile yes
The number of times this cycle repeats 1
Name of the cruise BOCATS - RREX
Date of last update of the metadata of the platform 13/07/2016 16:00:00
Date of last update of the trajectory of the platform 18/06/2021 13:33:14
Version number of the data handbook 1,2
Theoretical time of end of ascent to surface 23
Profiler configuration - Periode de transmission en fin de vie (minute) 100
Profiler configuration - Duree maxi d activation ev en surface (cs) 2700
Profiler configuration - Volume transfere par l ev maxi autorise en profondeur (cm3) 30
Profiler configuration - Duree maxi d activation pompe en profondeur (cs) 400
Profiler configuration - Duree maxi d activation pompe en remontee (cs) 2000
Profiler configuration - Dur?e nominale d activation pompe en emergence (cs) 30000
Profiler configuration - Tolerance sur l atteinte de la pression de consigne (dBar) 30
Profiler configuration - Pression maxi a ne pas depasser (dBar) 2100
Profiler configuration - Pression de debut de reduction de la duree d activation ev en surface (dBar) 4
Profiler configuration - Critere de pression de debut de plongee (dBar) 8
Profiler configuration - Nbre de positions hors tolerance autorise en derive conduisant a repositionnement 2
Profiler configuration - Mode de gestion de l echouage en descente a pression de derive 0
Profiler configuration - Critere d echouage: volume cumule (cm3) 100
Profiler configuration - Pression en dessous de laquelle le flotteur reste pose en attente profil remontee (dBar) 200
Profiler configuration - Diminution de la pression visee en cas d echouage (dBar) 50
Profiler configuration - Tolerance sur maintien de la pression de consigne (dBar) 50
Profiler configuration - Mode d acquisition de la mesure 1
Profiler configuration - Periode d alternance profil - si=1, pas d alternance (jour) 1
Profiler configuration - Profondeur de profil alterne (dBar) 2000
Profiler configuration - Vitesse moyenne descente (mm/s) 27
Profiler configuration - Increment de profondeur de consigne a chaque cycle (dBar) 0
Profiler configuration - Coefficient de calibrage pression A 1.376
Profiler configuration - Coefficient de calibrage pression B -137.15
Firmware version 5817A08
Meteorology MODERATE SEAS 2 BEAUFORT
Delay Before Mission 0
Period Descent Profile 0
Period Ascent Profile 10
INTERMEDIATE SURFACE THRESHOLD 10
Depth intermediate threshold 500
Surface Slice Thickness 1
Intermediate Slice Thickness 10
Depth Slice Thickness 25
PRES when the SBE pump is switched off 5
Anderaa calibration coeff C0 0.0031101
Anderaa calibration coeff C1 0.000132824
Anderaa calibration coeff C2 0.00000251201
Anderaa calibration coeff C3 230.845
Anderaa calibration coeff C4 -0.37422
Anderaa calibration coeff C5 -57.9957
Anderaa calibration coeff C6 4.55207
Optode type 1
Average ascent speed 90
Anderaa optode phase coeff 0 0
Anderaa optode phase coeff 1 1
Anderaa optode phase coeff 2 0
Anderaa optode phase coeff 3 0
CTD cut-off pressure 2
preset duration of the 'up' time (start of ascent to start of descent) 5.5
maximum cycles 500
Argos telemetry repetition 25
Argos transmission min time 10
Prelude duration 180
Category of instrument FLOAT
Id of the sail connector DO-S31-1405
Number of the bluetooth connection 2014 01 51
Firmware checksum A261
Comment on float visual inspection done just before deployment OK
Comment on ballast visual inspection done just before deployment OK
Startup date of the float 10/07/2016 23:00:00
Description of the float buoyancy just after deployment OK
Name of the deployment operator S. LEIZOUR
Method used to deploy the float MANUAL
Comment on the float deployment CTD 72
Hex value of the transmission identifier DA6E64C
Comment on float visual inspection done during acceptance tests ok
Comment on ballast visual inspection done during acceptance tests ok
Float firmware version during acceptance tests 5817A08
Float firmware checksum during acceptance tests A121
Float clock set at the beginning of the acceptance tests yes
Float battery voltage measured at the beginning of the acceptance tests 108
Float internal vacuum measured with a full bladder at the beginning of the acceptance tests 650
Internal vacuum calibration coefficient A during the acceptance tests 1.376
Internal vacuum calibration coefficient B during the acceptance tests -137.15
Output of the '?S' command performed at the beginning of the acceptance tests 0cbar 11531mdc 6mpsu
Spy mode set to ON at the beginning of the acceptance tests ok
Show mode set to OFF at the beginning of the acceptance tests ok
Mission armed at the beginning of the acceptance tests ok
Delay between magnet removal and the 5 slow valve actions performed by the float during acceptance tests 5'
Delay between magnet removal and the CTD pump activation performed by the float during acceptance tests 1'16
Delay between magnet removal and the 5 quick valve actions performed by the float during acceptance tests 1'36
Delay between magnet removal and the pump activation performed by the float during acceptance tests 1'50
Delay between magnet removal and the internal check performed by the float during acceptance tests 2'
Delay between magnet removal and the Argos transmission test performed by the float during acceptance tests 3'45
Description of the float buoyancy during acceptance tests tape gros diametre
Drift of the float clock during acceptance tests derive -24s
Float clock set at the end of the acceptance tests yes
Output of the '?S' command performed at the end of the acceptance tests 0cbar 12990mdc 15mpsu
Float battery voltage measure at the end of the acceptance tests 106
Float internal vacuum measured during the acceptance tests 655
Comment on internal vacuums measured during the acceptance tests raz capteur pression
Comment on float visual inspection done during the pre-deployment check OK
Comment on ballast visual inspection done during the pre-deployment check OK
Float clock set during the pre-deployment check OK
Float battery voltage measured during the pre-deployment check 108
Float internal vacuum measured during the pre-deployment check 655
Internal vacuum calibration coefficient A during the pre-deployment check 1.376
Internal vacuum calibration coefficient B during the pre-deployment check -137.15
Output of the '?S' command performed during the pre-deployment check S: 0cBars 13011mdc 24mPSU
Spy mode set to ON during the pre-deployment check OK
Show mode set to OFF during the pre-deployment check OK
Mission armed during the pre-deployment check OK
Period of the pressure checks during the float ascent to surface 2
pression stab remontée 10
Platform type PROVOR
Threshold used by the float to stop ascent speed control and pump actions. 10
Type of sensor from L22 SeaVox Device Catalogue TOOL0669
Type of sensor from L22 SeaVox Device Catalogue TOOL0826
Date of last update of the tech data of the platform 18/06/2021 13:38:20
Configuration phases
Total time of a cycle : descent + parking + ascent + surface Preset duration of the down time (start of descent to start of ascent) Preset duration of the up time (start of ascent to start of descent) Pressure of subsurface drifts Deepest pressure sampled in the ascending profile
240 1000 2000
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES KISTLER KISTLER_2900PSIA 2096258
CTD_TEMP SBE SBE41CP_V2 5951
CTD_CNDC SBE SBE41CP_V2 5951
OPTODE_DOXY AANDERAA AANDERAA_OPTODE_4330 1384
Physical parameters
Name Units Accuracy Resolution
CTD_PRES decibar 2,4 0,1
CTD_TEMP degree_Celsius 0,002 0,001
CTD_CNDC psu 0,005 0,001
OPTODE_DOXY micromole/kg 0,1 0,001
OPTODE_DOXY degree
Calibrations
Parameter Equation Coefficients Comment
PRES
TEMP
PSAL
DOXY
TPHASE_DOXY
Technical parameters Details