Code 6901774
Name PROVOR-III Profiling Float
Description NAOS
Project NAOS
Institution LOV, Laboratoire Océanographique de Villefranche
Data Assembly Center IF : CORIOLIS
Activity Active
Status
Comment
First station date 25/06/2018 08:24:00
Last station date 09/06/2021 10:27:00
Float cycles 176, 175, 174, 173, 172, 171, 170, 169, 168, 167, 166, 165, 164, 163, 162, 161, 160, 159, 158, 157, 156, 155, 154, 153, 152, 151, 150, 149, 148, 147, 146, 145, 144, 143, 142, 141, 140, 139, 138, 137, 136, 135, 134, 133, 132, 131, 130, 129, 128, 127, 126, 125, 124, 123, 122, 121, 120, 119, 118, 117, 116, 115, 114, 113, 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 6, 5, 4, 3, 2, 1
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 6901774
(C) Coriolis data centre - 2021.06.13
T/S Diagram
Section chart


Overlayed profiles


Waterfall profiles


Configuration
Profiler TYPE PROVOR
Profiler VERSION 5.92
Profiler CRC TYPE 16
Profiler LAUNCH DATETIME 25/06/2018 06:21:00
Profiler LAUNCH LATITUDE 38.43
Profiler LAUNCH LONGITUDE 7.25
Profiler PROBE CODE 836
Profiler EXPERIMENT ID NAOS
Profiler CONDUCTIVITY ACCURACY 2
Platform activity flag A
The last valid station id of the platform 77635453
Bathy 2840
Data centre in charge of platform data processing IF
Positioning system GPS
Transmission identifier (ARGOS, ORBCOMM, etc.) lovbio094d
The telecommunications system used IRIDIUM
Model of the float MED_xxx__OA_lovbio094d
The name of the manufacturer NKE
Instrument type OIN-14SO-S4-11
Direction of the profiles B
Name of the principal investigator Fabrizio D'ORTENZIO
Quality on launch date, time and location 1
Quality on start date 1
Identifier of the deployment platform Tethys 2
Identifier of stations used to verify the first profile NO (mais bicorne realise une semaine avant)
Name of the cruise Bio Argo Med 2
Date of last update of the metadata of the platform 25/06/2018 16:00:00
Date of last update of the trajectory of the platform 09/06/2021 13:33:24
Version number of the data handbook 1.2
List of parameters with real-time calibration information DOXY
Calibration equation for this parameter PPOX_DOXY_ADJUSTED = a1 * PPOX_DOXY + a0
Calibration coefficients for this equation a1=1.10145, a0=0.0000
Comment applying to this parameter calibration Real-time doxy adjustment
Date of the calibration 20180625062100
Firmware version 1.07
The configuration of battery packs in the float 4DD LI
The type of controller board I535
The secondary type of controller board CAMAT256
The serial number of the primary controller board C134239-0005
The serial number of the secondary controller board I1405018
The float owner NAOS
The operating institution of the float LOV-CNRS-UPMC
Anderaa calibration coeff C0 0.00280961
Anderaa calibration coeff C1 0.000118637
Anderaa calibration coeff C2 0.0000024362
Anderaa calibration coeff C3 229.871
Anderaa calibration coeff C4 -0.325605
Anderaa calibration coeff C5 -56.6966
Anderaa calibration coeff C6 4.56435
Anderaa optode phase coeff 0 0
Anderaa optode phase coeff 1 1
Anderaa optode phase coeff 2 0
Anderaa optode phase coeff 3 0
Aanderaa Optode temp coeff 0 23.8137
Aanderaa Optode temp coeff 1 -0.0313626
Aanderaa Optode temp coeff 2 0.00000292056
Aanderaa Optode temp coeff 3 -0.00000000426222
Aanderaa Optode temp coeff 4 0
Aanderaa Optode temp coeff 5 0
Category of instrument FLOAT
Number of the SIM card 8988169234000798918
Number of the bluetooth connection 2014-06-005
Comment on float visual inspection done just before deployment OK
Comment on ballast visual inspection done just before deployment OK
Startup date of the float 25/06/2018 06:08:00
Description of the float buoyancy just after deployment Flotte correctement
Name of the deployment operator Benjamin Briat
Method used to deploy the float Crochet largueur
Comment on the float deployment RAS
Angle of Beta measurements (in angular degree) 124
Wavelength of ECO Beta #<DIM_LEVEL> measurements (in nanometer) 700
Wavelength of ECO sensor for emission of CDOM fluorescence measurements (in nanometer) 460
Wavelength of ECO sensor for excitation of CDOM fluorescence measurements (in nanometer) 370
Wavelength of ECO sensor for emission of CHLA fluorescence measurements (in nanometer) 695
Wavelength of ECO sensor for excitation of CHLA fluorescence measurements (in nanometer) 470
Vertical pressure offset due to the fact that the ECO sensor is not exactly at the CTD pressure (in dbar) 0.1
Bandwidth of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 10
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 380
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 412
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 490
Vertical pressure offset due to the fact that the OCR sensor is not exactly at the CTD pressure (in dbar) -0.08
Vertical pressure offset due to the fact that the OPTODE sensor is not exactly at the CTD pressure (in dbar) -0.6
Platform type PROVOR_III
Type of sensor from L22 SeaVox Device Catalogue TOOL0669
Type of sensor from L22 SeaVox Device Catalogue TOOL0826
Type of sensor from L22 SeaVox Device Catalogue TOOL1141
Comment on float internal checks before deployment (valve and pump actions, argos transmission check) OK
Float deployment height (m) 1
Ship speed during float deployment (kts) 2.5
Wind speed during float deplayment (Beaufort) 12 knts
Sea state during float deployment (calm, smooth, slight, moderate, rough, very rough, high, very high, phenomenal) Smooth
Optode is set up to perform measurements in air for calibration (yes/no) yes
Delay between CTD and Optode (in second) 0
New DARK value is provided (in pool or in lab) (yes/no) no
Date of last update of the tech data of the platform 09/06/2021 15:38:30
Configuration phases
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES KISTLER KISTLER_2900PSIA 2152000
CTD_TEMP SBE SBE41CP_V2 6040
CTD_CNDC SBE SBE41CP_V2 6040
OPTODE_DOXY AANDERAA AANDERAA_OPTODE_4330 1802
RADIOMETER_DOWN_IRR380 SATLANTIC SATLANTIC_OCR504_ICSW 40333
RADIOMETER_DOWN_IRR412 SATLANTIC SATLANTIC_OCR504_ICSW 40333
RADIOMETER_DOWN_IRR490 SATLANTIC SATLANTIC_OCR504_ICSW 40333
RADIOMETER_PAR SATLANTIC SATLANTIC_OCR504_ICSW 40333
FLUOROMETER_CHLA WETLABS ECO_FLBBCD 3664
BACKSCATTERINGMETER_BBP700 WETLABS ECO_FLBBCD 3664
FLUOROMETER_CDOM WETLABS ECO_FLBBCD 3664
Physical parameters
Name Units Accuracy Resolution
CTD_PRES decibar 2.4 1
CTD_TEMP degree_Celsius 0.002 0.001
CTD_CNDC psu 0.005 0.001
OPTODE_DOXY degree
OPTODE_DOXY degree
OPTODE_DOXY degree_Celsius
OPTODE_DOXY micromole/kg 10% 0.001
RADIOMETER_DOWN_IRR380 count
RADIOMETER_DOWN_IRR412 count
RADIOMETER_DOWN_IRR490 count
RADIOMETER_PAR count
RADIOMETER_DOWN_IRR380 W/m^2/nm
RADIOMETER_DOWN_IRR412 W/m^2/nm
RADIOMETER_DOWN_IRR490 W/m^2/nm
RADIOMETER_PAR microMoleQuanta/m^2/sec
FLUOROMETER_CHLA count
BACKSCATTERINGMETER_BBP700 count
FLUOROMETER_CDOM count
FLUOROMETER_CHLA mg/m3
BACKSCATTERINGMETER_BBP700 m-1
FLUOROMETER_CDOM ppb
Calibrations
Parameter Equation Coefficients Comment
PRES
TEMP
PSAL
C1PHASE_DOXY
C2PHASE_DOXY
TEMP_DOXY
DOXY
PPOX_DOXY
RAW_DOWNWELLING_IRRADIANCE380
RAW_DOWNWELLING_IRRADIANCE412
RAW_DOWNWELLING_IRRADIANCE490
RAW_DOWNWELLING_PAR
DOWN_IRRADIANCE380
DOWN_IRRADIANCE412
DOWN_IRRADIANCE490
DOWNWELLING_PAR
FLUORESCENCE_CHLA
BETA_BACKSCATTERING700
FLUORESCENCE_CDOM
CHLA
BBP700
CDOM
Technical parameters Details