Status
Comment
Login
Code 6902686
Name ARVOR DO Profiling Float
Description CORIOLIS - RREX
Project RREX
Institution IFREMER, Institut Français de Recherche pour l'Exploitation de la Mer
Data Assembly Center IF : CORIOLIS
Activity Active
Status
Comment
First station date 28/07/2017 22:05:00
Last station date 09/06/2021 06:57:00
Float cycles 142, 141, 140, 139, 138, 137, 136, 135, 134, 133, 132, 131, 130, 129, 128, 127, 126, 125, 124, 123, 122, 121, 120, 119, 118, 117, 116, 115, 114, 113, 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 6902686
(C) Coriolis data centre - 2021.06.15
T/S Diagram
Section chart

Overlayed profiles

Waterfall profiles

Configuration
Profiler TYPE PROVOR
Profiler VERSION 4.54
Profiler CRC TYPE 16
Profiler CYCLE PERIOD 10
Profiler IMMERSION DRIFT PERIOD 720
Profiler LAUNCH DATETIME 28/07/2017 18:01:00
Profiler LAUNCH LATITUDE 58.9709
Profiler LAUNCH LONGITUDE -32.0897
Profiler REFERENCE DATETIME 30/07/2017 00:00:00
Profiler REFERENCE INTERNAL DATE 24682
Profiler PROBE CODE 844
Profiler EXPERIMENT ID RREX
Profiler CONDUCTIVITY ACCURACY 2
Profiler PARKING DEPTH 1000
Profiler PROFILE DEPTH 2000
Platform activity flag A
The last valid station id of the platform 77635455
Bathy 1710
Profiler configuration - Reference day 2
Data centre in charge of platform data processing IF
Positioning system ARGOS
Transmission identifier (ARGOS, ORBCOMM, etc.) 150946
The telecommunications system used ARGOS
The program identifier used by the transmission system 2412
The frequency of transmission from the float 401 653 000
The repetition rate of transmission from the float 40
Model of the float ARVOR-DO
The name of the manufacturer NKE
Instrument type OIN-15-AR-DO-02
Direction of the profiles B
Name of the principal investigator Virginie THIERRY
Quality on launch date, time and location 1
Date (UTC) of the first descent of the float. 29/07/2017 02:47:00
Quality on start date 1
Identifier of the deployment platform ATALANTE
Identifier of stations used to verify the first profile yes - CTD n°40
The number of times this cycle repeats 1
Name of the cruise RREX
Date of last update of the metadata of the platform 24/08/2017 21:00:00
Date of last update of the trajectory of the platform 10/06/2021 18:33:26
Version number of the data handbook 1.2
Theoretical time of end of ascent to surface 7
Profiler configuration - Periode de transmission en fin de vie (minute) 100
Profiler configuration - Duree maxi d activation ev en surface (cs) 800
Profiler configuration - Volume transfere par l ev maxi autorise en profondeur (cm3) 11
Profiler configuration - Duree maxi d activation pompe en profondeur (cs) 290
Profiler configuration - Duree maxi d activation pompe en remontee (cs) 720
Profiler configuration - Dur?e nominale d activation pompe en emergence (cs) 24000
Profiler configuration - Tolerance sur l atteinte de la pression de consigne (dBar) 30
Profiler configuration - Pression maxi a ne pas depasser (dBar) 2100
Profiler configuration - Pression de debut de reduction de la duree d activation ev en surface (dBar) 1
Profiler configuration - Critere de pression de debut de plongee (dBar) 7
Profiler configuration - Nbre de positions hors tolerance autorise en derive conduisant a repositionnement 2
Profiler configuration - Mode de gestion de l echouage en descente a pression de derive 0
Profiler configuration - Critere d echouage: volume cumule (cm3) 36
Profiler configuration - Pression en dessous de laquelle le flotteur reste pose en attente profil remontee (dBar) 200
Profiler configuration - Diminution de la pression visee en cas d echouage (dBar) 50
Profiler configuration - Tolerance sur maintien de la pression de consigne (dBar) 50
Profiler configuration - Mode d acquisition de la mesure 1
Profiler configuration - Periode d alternance profil - si=1, pas d alternance (jour) 1
Profiler configuration - Profondeur de profil alterne (dBar) 2000
Profiler configuration - Vitesse moyenne descente (mm/s) 25
Profiler configuration - Increment de profondeur de consigne a chaque cycle (dBar) 0
Profiler configuration - Coefficient de calibrage pression A 1.194
Profiler configuration - Coefficient de calibrage pression B -122.16
Firmware version 5605B05
The manual version for the float 33-16-026
A standard format number to describe the data format for each float 102003
The configuration of battery packs in the float 2 WILPA1621A
The type of controller board I535
The serial number of the primary controller board C138177-0125
The float owner IFREMER
The operating institution of the float IFREMER
Delay Before Mission 0
Period Descent Profile 0
Period Ascent Profile 10
INTERMEDIATE SURFACE THRESHOLD 10
Depth intermediate threshold 500
Surface Slice Thickness 1
Intermediate Slice Thickness 10
Depth Slice Thickness 25
PRES when the SBE pump is switched off 5
Anderaa calibration coeff C0 0.00285329
Anderaa calibration coeff C1 0.000121033
Anderaa calibration coeff C2 0.00000247737
Anderaa calibration coeff C3 230.812
Anderaa calibration coeff C4 -0.319019
Anderaa calibration coeff C5 -55.9483
Anderaa calibration coeff C6 4.56302
Optode type 1
Average ascent speed 90
Anderaa optode phase coeff 0 0
Anderaa optode phase coeff 1 1
Anderaa optode phase coeff 2 0
Anderaa optode phase coeff 3 0
CTD cut-off pressure 2
preset duration of the 'up' time (start of ascent to start of descent) 5.5
maximum cycles 500
Argos telemetry repetition 25
Argos transmission min time 10
Prelude duration 180
Aanderaa Optode temp coeff 0 25.8001
Aanderaa Optode temp coeff 1 -0.0309525
Aanderaa Optode temp coeff 2 0.00000301783
Aanderaa Optode temp coeff 3 -0.00000000446915
Aanderaa Optode temp coeff 4 0
Aanderaa Optode temp coeff 5 0
Category of instrument FLOAT
Id of the sail connector 15ARDO02
Number of the bluetooth connection 2015 04 125
Firmware checksum 22D5
Comment on float visual inspection done just before deployment OK
Comment on ballast visual inspection done just before deployment OK
Startup date of the float 28/07/2017 17:47:00
Description of the float buoyancy just after deployment OK
Name of the deployment operator S.Le Reste/M.Hamon
Method used to deploy the float Quick release hook
Comment on the float deployment ras
Hex value of the transmission identifier E200C26
Comment on float visual inspection done during acceptance tests OK
Comment on ballast visual inspection done during acceptance tests OK
Float firmware version during acceptance tests 5605B05
Float firmware checksum during acceptance tests 22D5
Float clock set at the beginning of the acceptance tests YES
Float battery voltage measured at the beginning of the acceptance tests 10.8
Float internal vacuum measured with a full bladder at the beginning of the acceptance tests 605
Spy mode set to ON at the beginning of the acceptance tests OK
Show mode set to OFF at the beginning of the acceptance tests OK
Mission armed at the beginning of the acceptance tests OK
Startup date of the float for acceptance tests 25/01/2016 10:41:00
Drift of the float clock during acceptance tests -
Float battery voltage measure at the end of the acceptance tests 10.8
Float internal vacuum measured during the acceptance tests 610
Comment on internal vacuums measured during the acceptance tests OK
General comments on the acceptance tests OK
Comment on float visual inspection done during the pre-deployment check OK
Comment on ballast visual inspection done during the pre-deployment check OK
Float clock set during the pre-deployment check -
Float battery voltage measured during the pre-deployment check 10.8
Float internal vacuum measured during the pre-deployment check 600
Comment on internal vacuums measured during the acceptance tests OK
Spy mode set to ON during the pre-deployment check OK
Show mode set to OFF during the pre-deployment check OK
Mission armed during the pre-deployment check OK
General comments on the pre-deployment check Float programmed 27/04/2017
Period of the pressure checks during the float ascent to surface 2
pression stab remontée 10
Platform type ARVOR
Threshold used by the float to stop ascent speed control and pump actions. 10
Type of sensor from L22 SeaVox Device Catalogue TOOL0669
Type of sensor from L22 SeaVox Device Catalogue TOOL0826
Number of cycles for the first mission of a double mission Argos float (Arvor ARN 2013) 500
Comment on float internal checks before deployment (valve and pump actions, argos transmission check) OK
Float deployment height (m) 0
Ship speed during float deployment (kts) 2
Wind speed during float deplayment (Beaufort) 2
Sea state during float deployment (calm, smooth, slight, moderate, rough, very rough, high, very high, phenomenal) slight
Float clock value set during acceptance tests (dd/mm/yyyy hh:mm) ('!TI') 25/01/2016 10:00:00
PRES measurement done before acceptance deployment 0
TEMP measurement done before acceptance deployment 21.609
PSAL measurement done before acceptance deployment 0
Comment on float internal checks before acceptance deployment (valve and pump actions, argos transmission check) OK
Buoyancy description before acceptance deployment Water @ middle of P sensor
Buoyancy description after acceptance deployment Water @ middle of 1st CTD hole
PRES measurement done after acceptance deployment 1
TEMP measurement done after acceptance deployment 10.209
PSAL measurement done after acceptance deployment 0
Float firmware version at pre-deployment 5605B05
Float clock value set during pre-deployment (dd/mm/yyyy hh:mm) ('!TI') 28/01/2016 10:17:27
PRES measurement done during pre-deployment tests -1
TEMP measurement done during pre-deployment tests 11.852
PSAL measurement done during pre-deployment tests 6
Float waiting period before the surface ResetOffset CTD command (Arvor ARN 2013) 0
Date of last update of the tech data of the platform 10/06/2021 18:35:17
Configuration phases
Total time of a cycle : descent + parking + ascent + surface Preset duration of the down time (start of descent to start of ascent) Preset duration of the up time (start of ascent to start of descent) Pressure of subsurface drifts Deepest pressure sampled in the ascending profile
240 1000 2000
240 1000 2000
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES KISTLER KISTLER_2900PSIA 4673555
CTD_TEMP SBE SBE41CP_V2 7416
CTD_CNDC SBE SBE41CP_V2 7416
OPTODE_DOXY AANDERAA AANDERAA_OPTODE_4330 2185
Physical parameters
Name Units Accuracy Resolution
CTD_PRES decibar 2.4 0.1
CTD_TEMP degree_Celsius 0.002 0.001
CTD_CNDC psu 0.005 0.001
OPTODE_DOXY micromole/kg 10% 0.001
OPTODE_DOXY degree
Calibrations
Parameter Equation Coefficients Comment
PRES
TEMP
PSAL
DOXY
TPHASE_DOXY
Technical parameters Details