Code 6902740
Name PROVOR-III Profiling Float
Description remOcean
Project remOcean
Institution LOV, Laboratoire Océanographique de Villefranche
Data Assembly Center IF : CORIOLIS
Activity Active
Status
Comment
First station date 17/10/2016 08:51:00
Last station date 28/05/2021 09:50:00
Float cycles 191, 190, 189, 188, 187, 186, 185, 184, 183, 182, 181, 180, 179, 178, 177, 176, 175, 174, 173, 172, 171, 170, 169, 168, 167, 166, 165, 164, 163, 162, 161, 160, 159, 158, 157, 156, 155, 154, 153, 152, 151, 150, 149, 148, 147, 146, 145, 144, 143, 142, 141, 140, 139, 138, 137, 136, 135, 134, 133, 132, 131, 130, 129, 128, 127, 126, 125, 124, 123, 122, 121, 120, 119, 118, 117, 116, 115, 114, 113, 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 6902740
(C) Coriolis data centre - 2021.06.13
T/S Diagram
Section chart


Overlayed profiles


Waterfall profiles


Configuration
Profiler TYPE PROVOR
Profiler VERSION 5.92
Profiler CRC TYPE 16
Profiler LAUNCH DATETIME 17/10/2016 07:00:00
Profiler LAUNCH LATITUDE -20.6754
Profiler LAUNCH LONGITUDE -24.9959
Profiler PROBE CODE 836
Profiler EXPERIMENT ID remOcean
Profiler CONDUCTIVITY ACCURACY 2
Platform activity flag A
The last valid station id of the platform 77492021
Bathy 5690
Data centre in charge of platform data processing IF
Positioning system GPS
Transmission identifier (ARGOS, ORBCOMM, etc.) lovbio099c
The telecommunications system used IRIDIUM
Model of the float xxx_STG__OA_lovbio099c
The name of the manufacturer NKE
Instrument type OIN-15-S4-04
Direction of the profiles B
Name of the principal investigator Herve CLAUSTRE
Quality on launch date, time and location 1
Quality on start date 1
Identifier of the deployment platform RRS JAMES CLARK ROSS
Identifier of stations used to verify the first profile YES
Name of the cruise AMT26 (JR16001)
Date of last update of the metadata of the platform 26/10/2016 16:00:00
Date of last update of the trajectory of the platform 28/05/2021 12:33:37
Version number of the data handbook 1.2
List of parameters with real-time calibration information DOXY
List of parameters with real-time calibration information PSAL
Calibration equation for this parameter PPOX_DOXY_ADJUSTED = a1 * PPOX_DOXY + a0
Calibration equation for this parameter PSAL_ADJUSTED = a1 * PSAL + a0
Calibration coefficients for this equation a1=1, a0=0.0000
Calibration coefficients for this equation a1=1.02490, a0=0.0000
Comment applying to this parameter calibration Real-time doxy adjustment
Comment applying to this parameter calibration Real-time salinity adjustment
Date of the calibration 20161017070000
Date of the calibration 20200203000000
Firmware version 1.07
The configuration of battery packs in the float 4DD LI
The type of controller board I535
The secondary type of controller board CAMAT256
The serial number of the primary controller board C138177_0011
The serial number of the secondary controller board I439013
The float owner remOcean
The operating institution of the float LOV
Anderaa calibration coeff C0 0.00267426
Anderaa calibration coeff C1 0.000113798
Anderaa calibration coeff C2 0.00000224299
Anderaa calibration coeff C3 229.347
Anderaa calibration coeff C4 -0.363091
Anderaa calibration coeff C5 -55.5069
Anderaa calibration coeff C6 4.57741
Anderaa optode phase coeff 0 0.593
Anderaa optode phase coeff 1 1
Anderaa optode phase coeff 2 0
Anderaa optode phase coeff 3 0
Aanderaa Optode temp coeff 0 27.1487
Aanderaa Optode temp coeff 1 -0.0315272
Aanderaa Optode temp coeff 2 0.00000325669
Aanderaa Optode temp coeff 3 -0.00000000467253
Aanderaa Optode temp coeff 4 0
Aanderaa Optode temp coeff 5 0
Category of instrument FLOAT
Number of the SIM card 8988169234000798892
Number of the bluetooth connection 2015 04 011
Comment on float visual inspection done just before deployment OK
Comment on ballast visual inspection done just before deployment OK
Startup date of the float 17/10/2016 06:52:00
Name of the deployment operator DALL'OLMO GIORGIO
Method used to deploy the float crane
Comment on the float deployment CTD048
Angle of Beta measurements (in angular degree) 124
Wavelength of ECO Beta #<DIM_LEVEL> measurements (in nanometer) 700
Wavelength of ECO sensor for emission of CDOM fluorescence measurements (in nanometer) 460
Wavelength of ECO sensor for excitation of CDOM fluorescence measurements (in nanometer) 370
Wavelength of ECO sensor for emission of CHLA fluorescence measurements (in nanometer) 695
Wavelength of ECO sensor for excitation of CHLA fluorescence measurements (in nanometer) 470
Vertical pressure offset due to the fact that the ECO sensor is not exactly at the CTD pressure (in dbar) 0.1
Bandwidth of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 10
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 380
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 412
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 490
Vertical pressure offset due to the fact that the OCR sensor is not exactly at the CTD pressure (in dbar) -0.08
Vertical pressure offset due to the fact that the OPTODE sensor is not exactly at the CTD pressure (in dbar) -0.5
State of the vector board show mode (0: OFF; 1: ON) 0
State of the sensor board show mode (0: OFF; 1: ON) 0
Platform type PROVOR_III
Type of sensor from L22 SeaVox Device Catalogue TOOL0669
Type of sensor from L22 SeaVox Device Catalogue TOOL0826
Type of sensor from L22 SeaVox Device Catalogue TOOL1141
Comment on float internal checks before deployment (valve and pump actions, argos transmission check) OK
Ship speed during float deployment (kts) 0
Sea state during float deployment (calm, smooth, slight, moderate, rough, very rough, high, very high, phenomenal) Slight (0.5 to 1.25 m)
Optode is set up to perform measurements in air for calibration (yes/no) yes
Delay between CTD and Optode (in second) 0
New DARK value is provided (in pool or in lab) (yes/no) yes
Date of last update of the tech data of the platform 05/06/2021 22:54:05
Configuration phases
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES KISTLER KISTLER_2900PSIA 4582900
CTD_TEMP SBE SBE41CP_V2 6714
CTD_CNDC SBE SBE41CP_V2 6714
OPTODE_DOXY AANDERAA AANDERAA_OPTODE_4330 2593
RADIOMETER_DOWN_IRR380 SATLANTIC SATLANTIC_OCR504_ICSW 40367
RADIOMETER_PAR SATLANTIC SATLANTIC_OCR504_ICSW 40367
RADIOMETER_DOWN_IRR412 SATLANTIC SATLANTIC_OCR504_ICSW 40367
RADIOMETER_DOWN_IRR490 SATLANTIC SATLANTIC_OCR504_ICSW 40367
FLUOROMETER_CHLA WETLABS ECO_FLBBCD 3798
BACKSCATTERINGMETER_BBP700 WETLABS ECO_FLBBCD 3798
FLUOROMETER_CDOM WETLABS ECO_FLBBCD 3798
Physical parameters
Name Units Accuracy Resolution
CTD_PRES decibar 2.4 1
CTD_TEMP degree_Celsius 0.002 0.001
CTD_CNDC psu 0.005 0.001
OPTODE_DOXY degree
OPTODE_DOXY degree
OPTODE_DOXY degree_Celsius
OPTODE_DOXY micromole/kg 10% 0.001
RADIOMETER_DOWN_IRR380 count
RADIOMETER_DOWN_IRR412 count
RADIOMETER_DOWN_IRR490 count
RADIOMETER_PAR count
RADIOMETER_DOWN_IRR380 W/m^2/nm
RADIOMETER_DOWN_IRR412 W/m^2/nm
RADIOMETER_DOWN_IRR490 W/m^2/nm
RADIOMETER_PAR microMoleQuanta/m^2/sec
FLUOROMETER_CHLA count
BACKSCATTERINGMETER_BBP700 count
FLUOROMETER_CDOM count
FLUOROMETER_CHLA mg/m3
BACKSCATTERINGMETER_BBP700 m-1
FLUOROMETER_CDOM ppb
Calibrations
Parameter Equation Coefficients Comment
PRES
TEMP
PSAL
C1PHASE_DOXY
C2PHASE_DOXY
TEMP_DOXY
DOXY
PPOX_DOXY
RAW_DOWNWELLING_IRRADIANCE380
RAW_DOWNWELLING_IRRADIANCE412
RAW_DOWNWELLING_IRRADIANCE490
RAW_DOWNWELLING_PAR
DOWN_IRRADIANCE380
DOWN_IRRADIANCE412
DOWN_IRRADIANCE490
DOWNWELLING_PAR
FLUORESCENCE_CHLA
BETA_BACKSCATTERING700
FLUORESCENCE_CDOM
CHLA
BBP700
CDOM
Technical parameters Details