Status
Comment
Login
Code 6902899
Name PROVOR-IV Profiling Float
Description NAOS-France
Project Euro-Argo RISE
Institution LOV, Laboratoire Océanographique de Villefranche
Data Assembly Center IF : CORIOLIS
Activity Active
Status
Comment
First station date 11/12/2019 16:15:00
Last station date 12/06/2021 11:42:00
Float cycles 185, 184, 183, 182, 181, 180, 179, 178, 177, 176, 175, 174, 173, 172, 171, 170, 169, 168, 167, 166, 165, 164, 163, 162, 161, 160, 159, 158, 157, 156, 155, 154, 153, 152, 151, 150, 149, 148, 147, 146, 145, 144, 143, 142, 141, 140, 139, 138, 137, 136, 135, 134, 133, 132, 131, 130, 129, 128, 127, 126, 125, 124, 123, 122, 121, 120, 119, 118, 117, 116, 115, 114, 113, 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 6902899
(C) Coriolis data centre - 2021.06.13
T/S Diagram
Section chart

Overlayed profiles

Waterfall profiles

Configuration
Profiler TYPE PROVOR
Profiler VERSION 5.9
Profiler CRC TYPE 16
Profiler LAUNCH DATETIME 11/12/2019 14:52:47
Profiler LAUNCH LATITUDE 43.412
Profiler LAUNCH LONGITUDE 7.8589
Profiler PROBE CODE 836
Profiler EXPERIMENT ID Euro-Argo RISE
Profiler CONDUCTIVITY ACCURACY 2
Platform activity flag A
The last valid station id of the platform 77684277
Bathy 2339
Data centre in charge of platform data processing IF
Positioning system GPS
Transmission identifier (ARGOS, ORBCOMM, etc.) lovbio066e
The telecommunications system used IRIDIUM
Model of the float MED_xxx___A_lovbio066e
The name of the manufacturer NKE
Instrument type OIN13-S4-06
Direction of the profiles B
Name of the principal investigator Fabrizio D'ORTENZIO
Quality on launch date, time and location 1
Quality on start date 1
Identifier of the deployment platform Thetys II
Name of the cruise Boussole
Date of last update of the metadata of the platform 13/12/2019 16:00:00
Date of last update of the trajectory of the platform 12/06/2021 15:34:41
Version number of the data handbook 1.2
Firmware version 1.07
The configuration of battery packs in the float 4DD LI
The type of controller board I535
The secondary type of controller board CAMAT256
The serial number of the primary controller board C128040013
The serial number of the secondary controller board I1311012
The float owner EA-RISE
The operating institution of the float LOV-CNRS-UPMC
Category of instrument FLOAT
Number of the SIM card 8988169234000407312
Number of the bluetooth connection 2013-07-013
Comment on float visual inspection done just before deployment OK
Startup date of the float 11/12/2019 14:38:07
Angle of Beta measurements (in angular degree) 124
Wavelength of ECO Beta #<DIM_LEVEL> measurements (in nanometer) 700
Wavelength of ECO sensor for emission of CDOM fluorescence measurements (in nanometer) 460
Wavelength of ECO sensor for excitation of CDOM fluorescence measurements (in nanometer) 370
Wavelength of ECO sensor for emission of CHLA fluorescence measurements (in nanometer) 695
Wavelength of ECO sensor for excitation of CHLA fluorescence measurements (in nanometer) 470
Vertical pressure offset due to the fact that the ECO sensor is not exactly at the CTD pressure (in dbar) 0.1
Bandwidth of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 10
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 380
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 412
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 490
Vertical pressure offset due to the fact that the OCR sensor is not exactly at the CTD pressure (in dbar) -0.08
Vertical pressure offset due to the fact that the OPTODE sensor is not exactly at the CTD pressure (in dbar) 0
Vertical pressure offset due to the fact that the SUNA sensor is not exactly at the CTD pressure (in dbar) 1.5
State of the vector board show mode (0: OFF; 1: ON) 0
State of the sensor board show mode (0: OFF; 1: ON) 0
Platform type PROVOR_III
Type of sensor from L22 SeaVox Device Catalogue TOOL0669
Type of sensor from L22 SeaVox Device Catalogue TOOL1141
Ship speed during float deployment (kts) 1
Wind speed during float deplayment (Beaufort) 3
Sea state during float deployment (calm, smooth, slight, moderate, rough, very rough, high, very high, phenomenal) Slight (0.5 to 1.25 m)
Optode is set up to perform measurements in air for calibration (yes/no) no
Delay between CTD and Optode (in second) 0
New DARK value is provided (in pool or in lab) (yes/no) no
Date of last update of the tech data of the platform 12/06/2021 15:41:49
Configuration phases
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES SBE SBE41CP 2126860
CTD_TEMP SBE SBE41CP 5345
CTD_CNDC SBE SBE41CP 5345
RADIOMETER_DOWN_IRR380 SATLANTIC SATLANTIC_OCR504_ICSW 40264
RADIOMETER_DOWN_IRR412 SATLANTIC SATLANTIC_OCR504_ICSW 40264
RADIOMETER_DOWN_IRR490 SATLANTIC SATLANTIC_OCR504_ICSW 40264
RADIOMETER_PAR SATLANTIC SATLANTIC_OCR504_ICSW 40264
FLUOROMETER_CHLA WETLABS ECO_FLBBCD 3112
BACKSCATTERINGMETER_BBP700 WETLABS ECO_FLBBCD 3112
FLUOROMETER_CDOM WETLABS ECO_FLBBCD 3112
Physical parameters
Name Units Accuracy Resolution
CTD_PRES decibar 2.4 1
CTD_TEMP degree_Celsius 0.002 0.001
CTD_CNDC psu 0.005 0.001
RADIOMETER_DOWN_IRR380 count
RADIOMETER_DOWN_IRR412 count
RADIOMETER_DOWN_IRR490 count
RADIOMETER_PAR count
RADIOMETER_DOWN_IRR380 W/m^2/nm
RADIOMETER_DOWN_IRR412 W/m^2/nm
RADIOMETER_DOWN_IRR490 W/m^2/nm
RADIOMETER_PAR microMoleQuanta/m^2/sec
FLUOROMETER_CHLA count
BACKSCATTERINGMETER_BBP700 count
FLUOROMETER_CDOM count
FLUOROMETER_CHLA mg/m3
BACKSCATTERINGMETER_BBP700 m-1
FLUOROMETER_CDOM ppb
Calibrations
Parameter Equation Coefficients Comment
PRES
TEMP
PSAL
RAW_DOWNWELLING_IRRADIANCE380
RAW_DOWNWELLING_IRRADIANCE412
RAW_DOWNWELLING_IRRADIANCE490
RAW_DOWNWELLING_PAR
DOWN_IRRADIANCE380
DOWN_IRRADIANCE412
DOWN_IRRADIANCE490
DOWNWELLING_PAR
FLUORESCENCE_CHLA
BETA_BACKSCATTERING700
FLUORESCENCE_CDOM
CHLA
BBP700
CDOM
Technical parameters Details