Status
Comment
Login
Code 6903091
Name PROVOR-III Profiling Float
Description GMMC CNES
Project SENOX
Institution LOV, Laboratoire Océanographique de Villefranche
Data Assembly Center IF : CORIOLIS
Activity Active
Status
Comment
First station date 06/03/2021 00:45:00
Last station date 10/06/2021 12:42:00
Float cycles 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 6903091
(C) Coriolis data centre - 2021.06.18
T/S Diagram
Section chart


Overlayed profiles


Waterfall profiles


Configuration
Profiler TYPE PROVOR
Profiler VERSION 6.11
Profiler CRC TYPE 16
Profiler LAUNCH DATETIME 05/03/2021 22:55:00
Profiler LAUNCH LATITUDE 8.9745
Profiler LAUNCH LONGITUDE -20.0515
Profiler PROBE CODE 836
Profiler EXPERIMENT ID SENOX
Profiler CONDUCTIVITY ACCURACY 2
Platform activity flag A
The last valid station id of the platform 77659334
Bathy 3440
Data centre in charge of platform data processing IF
Positioning system GPS
Transmission identifier (ARGOS, ORBCOMM, etc.) lovbio117c
The telecommunications system used IRIDIUM
Model of the float xxx_xxx__OA_lovbio117c
The name of the manufacturer NKE
Instrument type P41308-19FR001
Direction of the profiles B
Name of the principal investigator Xavier Capet
Quality on launch date, time and location 1
Quality on start date 1
Identifier of the deployment platform THALASSA
Identifier of stations used to verify the first profile yes
Name of the cruise PIRATA FR31
Date of last update of the metadata of the platform 11/03/2021 15:00:00
Date of last update of the trajectory of the platform 10/06/2021 16:35:25
Version number of the data handbook 1.2
List of parameters with real-time calibration information DOXY
Calibration equation for this parameter PPOX_DOXY_ADJUSTED = a1 * PPOX_DOXY + a0
Calibration coefficients for this equation a1=1.0836, a0=0.0000
Comment applying to this parameter calibration initial assessment by coriolis according to https://doi.org/10.13155/76709 based on case1_1 (cycles 2 3 4 5 6)
Date of the calibration 20210305225500
Firmware version 3.02
The configuration of battery packs in the float 4DD LI
The type of controller board I535
The secondary type of controller board CAMAT256
The serial number of the primary controller board C163297-0009
The serial number of the secondary controller board I1723026
The float owner Bioargo-CNES-GMMC
The operating institution of the float LOCEAN_Paris
Anderaa calibration coeff C0 2.686090E-03
Anderaa calibration coeff C1 1.188380E-04
Anderaa calibration coeff C2 2.095540E-06
Anderaa calibration coeff C3 2.754800E+02
Anderaa calibration coeff C4 -3.404510E-01
Anderaa calibration coeff C5 -5.901390E+01
Anderaa calibration coeff C6 5.476180E+00
Anderaa optode phase coeff 0 -1.071374
Anderaa optode phase coeff 1 1
Anderaa optode phase coeff 2 0
Anderaa optode phase coeff 3 0
Aanderaa Optode temp coeff 0 2.242430E+01
Aanderaa Optode temp coeff 1 -3.184010E-02
Aanderaa Optode temp coeff 2 2.983990E-06
Aanderaa Optode temp coeff 3 -4.232020E-09
Aanderaa Optode temp coeff 4 0.000000E+00
Aanderaa Optode temp coeff 5 0.000000E+00
Category of instrument FLOAT
Number of the SIM card 8988169234002511533
Number of the bluetooth connection 2018-09-0009
Comment on float visual inspection done just before deployment OK
Startup date of the float 05/03/2021 22:52:00
Description of the float buoyancy just after deployment ok
Name of the deployment operator Fabrice Roubaud
Method used to deploy the float croc largable avec la potence
Angle of Beta measurements (in angular degree) 124
Wavelength of ECO Beta #<DIM_LEVEL> measurements (in nanometer) 700
Wavelength of ECO sensor for emission of CDOM fluorescence measurements (in nanometer) 460
Wavelength of ECO sensor for excitation of CDOM fluorescence measurements (in nanometer) 370
Wavelength of ECO sensor for emission of CHLA fluorescence measurements (in nanometer) 695
Wavelength of ECO sensor for excitation of CHLA fluorescence measurements (in nanometer) 470
Vertical pressure offset due to the fact that the ECO sensor is not exactly at the CTD pressure (in dbar) 0.1
Bandwidth of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 10
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 380
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 412
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 490
Vertical pressure offset due to the fact that the OCR sensor is not exactly at the CTD pressure (in dbar) -0.08
Vertical pressure offset due to the fact that the OPTODE sensor is not exactly at the CTD pressure (in dbar) -0.3
State of the vector board show mode (0: OFF; 1: ON) 0
State of the sensor board show mode (0: OFF; 1: ON) 0
Platform type PROVOR_III
Type of sensor from L22 SeaVox Device Catalogue TOOL0625
Type of sensor from L22 SeaVox Device Catalogue TOOL0669
Type of sensor from L22 SeaVox Device Catalogue TOOL0826
Type of sensor from L22 SeaVox Device Catalogue TOOL1141
Float deployment height (m) 1
Ship speed during float deployment (kts) 2
Wind speed during float deplayment (Beaufort) 8kn
Sea state during float deployment (calm, smooth, slight, moderate, rough, very rough, high, very high, phenomenal) smooth
Optode is set up to perform measurements in air for calibration (yes/no) yes
Delay between CTD and Optode (in second) 0
New DARK value is provided (in pool or in lab) (yes/no) no
Calibration adjusted error 10
Code (used by the decoder) of the method used to estimate adjustment error 1_1
Date of last update of the tech data of the platform 10/06/2021 16:43:13
Configuration phases
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES SBE SBE41CP 10650694
CTD_TEMP SBE SBE41CP 9902
CTD_CNDC SBE SBE41CP 9902
OPTODE_DOXY AANDERAA AANDERAA_OPTODE_4330 3002
RADIOMETER_DOWN_IRR380 SATLANTIC SATLANTIC_OCR504_ICSW 42000
RADIOMETER_DOWN_IRR412 SATLANTIC SATLANTIC_OCR504_ICSW 42000
RADIOMETER_DOWN_IRR490 SATLANTIC SATLANTIC_OCR504_ICSW 42000
RADIOMETER_PAR SATLANTIC SATLANTIC_OCR504_ICSW 42000
FLUOROMETER_CHLA WETLABS ECO_FLBBCD 5790
BACKSCATTERINGMETER_BBP700 WETLABS ECO_FLBBCD 5790
FLUOROMETER_CDOM WETLABS ECO_FLBBCD 5790
Physical parameters
Name Units Accuracy Resolution
CTD_PRES decibar 2.4 1
CTD_TEMP degree_Celsius 0.002 0.001
CTD_CNDC psu 0.005 0.001
OPTODE_DOXY degree
OPTODE_DOXY degree
OPTODE_DOXY degree_Celsius
OPTODE_DOXY micromole/kg 10% 0.001
OPTODE_DOXY millibar
RADIOMETER_DOWN_IRR380 count
RADIOMETER_DOWN_IRR412 count
RADIOMETER_DOWN_IRR490 count
RADIOMETER_PAR count
RADIOMETER_DOWN_IRR380 W/m^2/nm
RADIOMETER_DOWN_IRR412 W/m^2/nm
RADIOMETER_DOWN_IRR490 W/m^2/nm
RADIOMETER_PAR microMoleQuanta/m^2/sec
FLUOROMETER_CHLA count
BACKSCATTERINGMETER_BBP700 count
FLUOROMETER_CDOM count
FLUOROMETER_CHLA mg/m3
BACKSCATTERINGMETER_BBP700 m-1
FLUOROMETER_CDOM ppb
Calibrations
Parameter Equation Coefficients Comment
PRES
TEMP
PSAL
C1PHASE_DOXY
C2PHASE_DOXY
TEMP_DOXY
DOXY
PPOX_DOXY
RAW_DOWNWELLING_IRRADIANCE380
RAW_DOWNWELLING_IRRADIANCE412
RAW_DOWNWELLING_IRRADIANCE490
RAW_DOWNWELLING_PAR
DOWN_IRRADIANCE380
DOWN_IRRADIANCE412
DOWN_IRRADIANCE490
DOWNWELLING_PAR
FLUORESCENCE_CHLA
BETA_BACKSCATTERING700
FLUORESCENCE_CDOM
CHLA
BBP700
CDOM
Technical parameters Details