Status
Comment
Login
Code 6903579
Name PROVOR III Profiling Float
Description Argo NORWAY
Project Norway-BGC-Argo
Institution Institute of Marine Research (IMR)
Data Assembly Center IF : CORIOLIS
Activity Active
Status
Comment
First station date 20/04/2021 19:56:00
Last station date 14/06/2021 11:37:00
Float cycles 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 6903579
(C) Coriolis data centre - 2021.06.16
T/S Diagram
Section chart


Overlayed profiles


Waterfall profiles


Configuration
Profiler TYPE PROVOR
Profiler VERSION 6.13
Profiler CRC TYPE 16
Profiler LAUNCH DATETIME 20/04/2021 16:02:00
Profiler LAUNCH LATITUDE 74.5
Profiler LAUNCH LONGITUDE -9
Profiler PROBE CODE 836
Profiler EXPERIMENT ID Norway-BGC-Argo
Profiler CONDUCTIVITY ACCURACY 2
Platform activity flag A
The last valid station id of the platform 77687655
Data centre in charge of platform data processing IF
Positioning system GPS
Transmission identifier (ARGOS, ORBCOMM, etc.) imrbio009c
The telecommunications system used IRIDIUM
Model of the float imr009c
The name of the manufacturer NKE
Instrument type P41306-20EU003
Direction of the profiles B
Name of the principal investigator Kjell Arne Mork
Quality on launch date, time and location 1
Quality on start date 1
Identifier of the deployment platform R/V Johan Hjort
Identifier of stations used to verify the first profile yes
Name of the cruise 2021205
Date of last update of the metadata of the platform 29/04/2021 19:00:00
Date of last update of the trajectory of the platform 14/06/2021 15:33:06
Version number of the data handbook 1.2
Firmware version V3_03
The manual version for the float 33-16-016
The type of battery packs in the float Lithium
The configuration of battery packs in the float 4DD LI
The type of controller board I535
The secondary type of controller board CAMAT256
The serial number of the primary controller board C200409-0092
The serial number of the secondary controller board I2043010
The float owner IMR
The operating institution of the float IMR
Anderaa calibration coeff C0 0.00283157
Anderaa calibration coeff C1 0.000122754
Anderaa calibration coeff C2 0.00000221009
Anderaa calibration coeff C3 177.484
Anderaa calibration coeff C4 -0.268175
Anderaa calibration coeff C5 -41.6352
Anderaa calibration coeff C6 3.56701
Anderaa optode phase coeff 0 -4.50000E-01
Anderaa optode phase coeff 1 1
Anderaa optode phase coeff 2 0
Anderaa optode phase coeff 3 0
Aanderaa Optode temp coeff 0 28.3366
Aanderaa Optode temp coeff 1 -0.0313071
Aanderaa Optode temp coeff 2 0.00000332902
Aanderaa Optode temp coeff 3 -0.00000000476915
Aanderaa Optode temp coeff 4 0
Aanderaa Optode temp coeff 5 0
Category of instrument FLOAT
Number of the SIM card 8988169234003166188
Number of the bluetooth connection C200107-0062-AC
Firmware checksum 2.00E+65
Comment on float visual inspection done just before deployment OK
Startup date of the float 20/04/2021 15:30:00
Name of the deployment operator Henrik S°iland
Method used to deploy the float manual
Comment on float visual inspection done during acceptance tests OK
Comment on ballast visual inspection done during acceptance tests OK
Float firmware version during acceptance tests V3_03
Wavelength of CROVER sensor for Beam attenuation measurements (in nanometer) 660
Angle of Beta measurements (in angular degree) 124
Wavelength of ECO Beta #<DIM_LEVEL> measurements (in nanometer) 532
Wavelength of ECO Beta #<DIM_LEVEL> measurements (in nanometer) 700
Wavelength of ECO sensor for emission of CDOM fluorescence measurements (in nanometer) 460
Wavelength of ECO sensor for excitation of CDOM fluorescence measurements (in nanometer) 370
Wavelength of ECO sensor for emission of CHLA fluorescence measurements (in nanometer) 695
Wavelength of ECO sensor for excitation of CHLA fluorescence measurements (in nanometer) 470
Vertical pressure offset due to the fact that the ECO sensor is not exactly at the CTD pressure (in dbar) 0.1
Bandwidth of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 10
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 380
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 412
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 490
Vertical pressure offset due to the fact that the OCR sensor is not exactly at the CTD pressure (in dbar) -0.08
Vertical pressure offset due to the fact that the OPTODE sensor is not exactly at the CTD pressure (in dbar) -0.3
Platform type PROVOR_III
Ship speed during float deployment (kts) 0
Optode is set up to perform measurements in air for calibration (yes/no) yes
Delay between CTD and Optode (in second) 0
New DARK value is provided (in pool or in lab) (yes/no) no
Date of last update of the tech data of the platform 14/06/2021 16:46:43
Configuration phases
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES SBE SBE41CP 11581404
CTD_TEMP SBE SBE41CP 41-13221
CTD_CNDC SBE SBE41CP 41-13221
OPTODE_DOXY AANDERAA AANDERAA_OPTODE_4330 3466
RADIOMETER_DOWN_IRR380 SATLANTIC SATLANTIC_OCR504_ICSW 42072
RADIOMETER_DOWN_IRR412 SATLANTIC SATLANTIC_OCR504_ICSW 42072
RADIOMETER_DOWN_IRR490 SATLANTIC SATLANTIC_OCR504_ICSW 42072
RADIOMETER_PAR SATLANTIC SATLANTIC_OCR504_ICSW 42072
FLUOROMETER_CHLA WETLABS ECO_FLBBCD 6466
BACKSCATTERINGMETER_BBP700 WETLABS ECO_FLBBCD 6466
FLUOROMETER_CDOM WETLABS ECO_FLBBCD 6466
Physical parameters
Name Units Accuracy Resolution
CTD_PRES decibar 2.4 1
CTD_TEMP degree_Celsius 0.002 0.001
CTD_CNDC psu 0.005 0.001
OPTODE_DOXY degree
OPTODE_DOXY degree
OPTODE_DOXY degree_Celsius
OPTODE_DOXY micromole/kg 10% 0.001
OPTODE_DOXY millibar
RADIOMETER_DOWN_IRR380 count
RADIOMETER_DOWN_IRR412 count
RADIOMETER_DOWN_IRR490 count
RADIOMETER_PAR count
RADIOMETER_DOWN_IRR380 W/m^2/nm
RADIOMETER_DOWN_IRR412 W/m^2/nm
RADIOMETER_DOWN_IRR490 W/m^2/nm
RADIOMETER_PAR microMoleQuanta/m^2/sec
FLUOROMETER_CHLA count
BACKSCATTERINGMETER_BBP700 count
FLUOROMETER_CDOM count
FLUOROMETER_CHLA mg/m3
BACKSCATTERINGMETER_BBP700 m-1
FLUOROMETER_CDOM ppb
Calibrations
Parameter Equation Coefficients Comment
PRES
TEMP
PSAL
C1PHASE_DOXY
C2PHASE_DOXY
TEMP_DOXY
DOXY
PPOX_DOXY
RAW_DOWNWELLING_IRRADIANCE380
RAW_DOWNWELLING_IRRADIANCE412
RAW_DOWNWELLING_IRRADIANCE490
RAW_DOWNWELLING_PAR
DOWN_IRRADIANCE380
DOWN_IRRADIANCE412
DOWN_IRRADIANCE490
DOWNWELLING_PAR
FLUORESCENCE_CHLA
BETA_BACKSCATTERING700
FLUORESCENCE_CDOM
CHLA
BBP700
CDOM
Technical parameters Details