Code 6903878
Name PROVOR CST4 Profiling Float
Description Euro Argo ERIC
Project EuroSea
Institution Euro-Argo
Data Assembly Center IF : CORIOLIS
Activity Active
Status
Comment
First station date 12/03/2021 19:39:00
Last station date 11/06/2021 12:26:00
Float cycles 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 6903878
(C) Coriolis data centre - 2021.06.13
T/S Diagram
Section chart


Overlayed profiles


Waterfall profiles


Configuration
Profiler TYPE PROVOR
Profiler VERSION 6.13
Profiler CRC TYPE 16
Profiler LAUNCH DATETIME 12/03/2021 17:15:00
Profiler LAUNCH LATITUDE -6.0628
Profiler LAUNCH LONGITUDE -10.0034
Profiler PROBE CODE 836
Profiler EXPERIMENT ID EuroSea
Profiler CONDUCTIVITY ACCURACY 2
Platform activity flag A
The last valid station id of the platform 77660499
Bathy 3558
Data centre in charge of platform data processing IF
Positioning system GPS
Transmission identifier (ARGOS, ORBCOMM, etc.) eribio011c
The telecommunications system used IRIDIUM
Model of the float PROVOR_CTS4
The name of the manufacturer NKE
Instrument type P43200-20EU008
Direction of the profiles B
Name of the principal investigator Laurent Coppola
Quality on launch date, time and location 1
Quality on start date 1
Identifier of the deployment platform RV THALASSA
Identifier of stations used to verify the first profile yes
Name of the cruise PIRATA FR31
Date of last update of the metadata of the platform 25/03/2021 14:00:00
Date of last update of the trajectory of the platform 11/06/2021 17:34:57
Version number of the data handbook 1.2
List of parameters with real-time calibration information DOXY
Calibration equation for this parameter PPOX_DOXY_ADJUSTED = a1 * PPOX_DOXY + a0
Calibration coefficients for this equation a1=1.0655,a0=0.0000
Comment applying to this parameter calibration initial assessment by coriolis according to https://doi.org/10.13155/76709 based on case1_1 (cycles 2 3 4 5 6)
Date of the calibration 20210312171500
Firmware version V3_03
The manual version for the float 33-16-016_rev17
The configuration of battery packs in the float 4DD LI
The type of controller board I535
The secondary type of controller board CAMAT256
The serial number of the primary controller board C200409-0124
The serial number of the secondary controller board I2043004
The float owner Euro-Argo ERIC
The operating institution of the float Euro-Argo ERIC
Anderaa calibration coeff C0 2.874203E-03
Anderaa calibration coeff C1 1.251287E-04
Anderaa calibration coeff C2 2.415920E-06
Anderaa calibration coeff C3 1.874061E+02
Anderaa calibration coeff C4 -2.204252E-01
Anderaa calibration coeff C5 -3.969955E+01
Anderaa calibration coeff C6 3.775773E+00
Anderaa optode phase coeff 0 -2.344
Anderaa optode phase coeff 1 1
Anderaa optode phase coeff 2 0
Anderaa optode phase coeff 3 0
Category of instrument FLOAT
Number of the SIM card 8988169234003166378
Number of the bluetooth connection C200107-0198-AC
Firmware checksum 2.00E+65
Comment on float visual inspection done just before deployment OK
Comment on ballast visual inspection done just before deployment OK
Startup date of the float 12/03/2021 17:10:00
Description of the float buoyancy just after deployment OK
Name of the deployment operator B.Bourles/J.Llido
Method used to deploy the float Crane starboard side
Comment on float visual inspection done during acceptance tests OK
Comment on ballast visual inspection done during acceptance tests OK
Float firmware version during acceptance tests V3_03
Wavelength of CROVER sensor for Beam attenuation measurements (in nanometer) 660
Angle of Beta measurements (in angular degree) 124
Wavelength of ECO Beta #<DIM_LEVEL> measurements (in nanometer) 532
Wavelength of ECO Beta #<DIM_LEVEL> measurements (in nanometer) 700
Wavelength of ECO sensor for emission of CDOM fluorescence measurements (in nanometer) 460
Wavelength of ECO sensor for excitation of CDOM fluorescence measurements (in nanometer) 370
Wavelength of ECO sensor for emission of CHLA fluorescence measurements (in nanometer) 695
Wavelength of ECO sensor for excitation of CHLA fluorescence measurements (in nanometer) 470
Vertical pressure offset due to the fact that the ECO sensor is not exactly at the CTD pressure (in dbar) 0.1
Bandwidth of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 10
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 380
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 412
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 490
Vertical pressure offset due to the fact that the OCR sensor is not exactly at the CTD pressure (in dbar) -0.08
Vertical pressure offset due to the fact that the OPTODE sensor is not exactly at the CTD pressure (in dbar) -0.3
Vertical pressure offset due to the fact that the SUNA sensor is not exactly at the CTD pressure (in dbar) 1.5
State of the vector board show mode (0: OFF; 1: ON) 0
State of the sensor board show mode (0: OFF; 1: ON) 0
Platform type PROVOR_III
Comment on float internal checks before deployment (valve and pump actions, argos transmission check) OK
Float deployment height (m) 0
Ship speed during float deployment (kts) 1.5
Wind speed during float deplayment (Beaufort) 2
Sea state during float deployment (calm, smooth, slight, moderate, rough, very rough, high, very high, phenomenal) Slight (0.5 to 1.25 m)
Optode is set up to perform measurements in air for calibration (yes/no) yes
Delay between CTD and Optode (in second) 0
New DARK value is provided (in pool or in lab) (yes/no) no
Coefficient for PH computing -1.421900000000000000000000000
Coefficient for PH computing -0.001037800000000000000000000
Coefficient for PH computing -0.003330400000000000000000000
Coefficient for PH computing 0.000021211000000000000000000
Coefficient for PH computing -0.000000034868000000000000000
Coefficient for PH computing 0.000000000031372000000000000
Coefficient for PH computing -0.000000000000015716000000000
Transistor pH coefficient F5 0.000000000000000004216400000
Transistor pH coefficient F6 -0.000000000000000000000475250
Calibration adjusted error 10
Code (used by the decoder) of the method used to estimate adjustment error 1_1
Date of last update of the tech data of the platform 11/06/2021 17:39:15
Configuration phases
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES DRUCK DRUCK_2900PSIA 11542764
CTD_TEMP SBE SBE41CP_V7.2.5 41-13402
CTD_CNDC SBE SBE41CP_V7.2.5 41-13402
OPTODE_DOXY AANDERAA AANDERAA_OPTODE_4330 3330
RADIOMETER_DOWN_IRR380 SATLANTIC SATLANTIC_OCR504_ICSW 42064
RADIOMETER_DOWN_IRR412 SATLANTIC SATLANTIC_OCR504_ICSW 42064
RADIOMETER_DOWN_IRR490 SATLANTIC SATLANTIC_OCR504_ICSW 42064
RADIOMETER_PAR SATLANTIC SATLANTIC_OCR504_ICSW 42064
FLUOROMETER_CHLA WETLABS ECO_FLBBCD 6461
BACKSCATTERINGMETER_BBP700 WETLABS ECO_FLBBCD 6461
FLUOROMETER_CDOM WETLABS ECO_FLBBCD 6461
TRANSISTOR_PH SBE SEAFET 10699
Physical parameters
Name Units Accuracy Resolution
CTD_PRES decibar 2.4 1
CTD_TEMP degree_Celsius 0.002 0.001
CTD_CNDC psu 0.005 0.001
OPTODE_DOXY degree
OPTODE_DOXY degree
OPTODE_DOXY degree_Celsius
OPTODE_DOXY micromole/kg 10% 0.001
OPTODE_DOXY millibar
RADIOMETER_DOWN_IRR380 count
RADIOMETER_DOWN_IRR412 count
RADIOMETER_DOWN_IRR490 count
RADIOMETER_PAR count
RADIOMETER_DOWN_IRR380 W/m^2/nm
RADIOMETER_DOWN_IRR412 W/m^2/nm
RADIOMETER_DOWN_IRR490 W/m^2/nm
RADIOMETER_PAR microMoleQuanta/m^2/sec
FLUOROMETER_CHLA count
BACKSCATTERINGMETER_BBP700 count
FLUOROMETER_CDOM count
FLUOROMETER_CHLA mg/m3
BACKSCATTERINGMETER_BBP700 m-1
FLUOROMETER_CDOM ppb
TRANSISTOR_PH volt
TRANSISTOR_PH dimensionless
TRANSISTOR_PH dimensionless
Calibrations
Parameter Equation Coefficients Comment
PRES
TEMP
PSAL
C1PHASE_DOXY
C2PHASE_DOXY
TEMP_DOXY
DOXY
PPOX_DOXY
RAW_DOWNWELLING_IRRADIANCE380
RAW_DOWNWELLING_IRRADIANCE412
RAW_DOWNWELLING_IRRADIANCE490
RAW_DOWNWELLING_PAR
DOWN_IRRADIANCE380
DOWN_IRRADIANCE412
DOWN_IRRADIANCE490
DOWNWELLING_PAR
FLUORESCENCE_CHLA
BETA_BACKSCATTERING700
FLUORESCENCE_CDOM
CHLA
BBP700
CDOM
VRS_PH
PH_IN_SITU_FREE
PH_IN_SITU_TOTAL
Technical parameters Details