Status
Comment
Login
Code 6904117
Name PROVOR CTS5 Profiling Float
Description Argo BSH
Project DARGO2025
Institution Bundesamt für Seeschifffahrt und Hydrographie (BSH)
Data Assembly Center IF : CORIOLIS
Activity Active
Status
Comment
First station date 01/02/2021 11:08:37
Last station date 14/06/2021 13:12:23
Float cycles 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 6904117
(C) Coriolis data centre - 2021.06.16
T/S Diagram
Section chart



Overlayed profiles



Waterfall profiles



Configuration
Profiler TYPE PROVOR
Profiler VERSION 7.12
Profiler CRC TYPE 16
Profiler LAUNCH DATETIME 01/02/2021 10:10:00
Profiler LAUNCH LATITUDE 57.3322
Profiler LAUNCH LONGITUDE 20.1803
Profiler PROBE CODE 834
Profiler EXPERIMENT ID DARGO2025
Profiler CONDUCTIVITY ACCURACY 2
Platform activity flag A
The last valid station id of the platform 77687682
Bathy 240
Data centre in charge of platform data processing IF
Positioning system GPS
Transmission identifier (ARGOS, ORBCOMM, etc.) bshuse002b
The telecommunications system used IRIDIUM
The name of the manufacturer NKE
Instrument type P53340-20DE002
Direction of the profiles B
Name of the principal investigator Henry Bittig
Quality on launch date, time and location 1
Quality on start date 1
Identifier of the deployment platform 06EZ ELISABETH MANN BORGESE
Identifier of stations used to verify the first profile yes
Name of the cruise EMB256
Date of last update of the metadata of the platform 26/01/2021 14:00:00
Date of last update of the trajectory of the platform 14/06/2021 17:33:37
Version number of the data handbook 1.2
List of parameters with real-time calibration information DOXY
Calibration equation for this parameter PPOX_DOXY_ADJUSTED = a1 * PPOX_DOXY + a0
Calibration coefficients for this equation a1=1.063, a0=-2.2000
Comment applying to this parameter calibration Henry Bittig 20210208
Date of the calibration 20210201000000
Firmware version 1.08.005
The configuration of battery packs in the float 2*130 Ah
The type of controller board APMT
The secondary type of controller board USEA
The serial number of the primary controller board 0x4E88
The float owner BSH
The operating institution of the float IF
Anderaa calibration coeff C0 3.401880E-03
Anderaa calibration coeff C1 1.478264E-04
Anderaa calibration coeff C2 2.640204E-06
Anderaa calibration coeff C3 1.775260E+02
Anderaa calibration coeff C4 -2.391158E-01
Anderaa calibration coeff C5 -4.121156E+01
Anderaa calibration coeff C6 3.429421E+00
Anderaa optode phase coeff 0 -7.590000E-01
Anderaa optode phase coeff 1 1
Anderaa optode phase coeff 2 0
Anderaa optode phase coeff 3 0
Category of instrument FLOAT
Number of the SIM card 8988169234003166162
Number of the bluetooth connection APMT Y20 No 0104
Comment on float visual inspection done just before deployment OK
Startup date of the float 01/02/2021 09:50:00
Name of the deployment operator Donath
Method used to deploy the float crane
Angle of Beta measurements (in angular degree) 124
Wavelength of ECO Beta #<DIM_LEVEL> measurements (in nanometer) 700
Wavelength of ECO sensor for emission of CDOM fluorescence measurements (in nanometer) 460
Wavelength of ECO sensor for excitation of CDOM fluorescence measurements (in nanometer) 370
Wavelength of ECO sensor for emission of CHLA fluorescence measurements (in nanometer) 695
Wavelength of ECO sensor for excitation of CHLA fluorescence measurements (in nanometer) 470
Vertical pressure offset due to the fact that the ECO sensor is not exactly at the CTD pressure (in dbar) 0.1
Bandwidth of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 10
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 380
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 412
Wavelength of OCR sensor DOWNWELLING IRRADIANCE #<DIM_LEVEL> measurements (in nanometer) 490
Vertical pressure offset due to the fact that the OCR sensor is not exactly at the CTD pressure (in dbar) -0.08
Vertical pressure offset due to the fact that the OPTODE sensor is not exactly at the CTD pressure (in dbar) -0.3
Vertical pressure offset due to the fact that the SUNA sensor is not exactly at the CTD pressure (in dbar) 1.2
Suna with scoop which redirects flow through Suna optics (values: 1 = Yes, 0 = No) 0
The APS frame definition allows for a variable number of spectrometer pixels (also called channels) to be included in the frame. The two pixel values are configured indirectly via the wavelength range of the spectrum to be output. 36
The APS frame definition allows for a variable number of spectrometer pixels (also called channels) to be included in the frame. The two pixel values are configured indirectly via the wavelength range of the spectrum to be output. 126
Platform type PROVOR_V
Type of sensor from L22 SeaVox Device Catalogue TOOL0669
Type of sensor from L22 SeaVox Device Catalogue TOOL0826
Type of sensor from L22 SeaVox Device Catalogue TOOL1141
Comment on float internal checks before deployment (valve and pump actions, argos transmission check) OK
Float deployment height (m) 0
Ship speed during float deployment (kts) 0.5
Wind speed during float deplayment (Beaufort) 4
Sea state during float deployment (calm, smooth, slight, moderate, rough, very rough, high, very high, phenomenal) Slight (0.5 to 1.25 m)
Optode is set up to perform measurements in air for calibration (yes/no) yes
First cycle to process 10
Calibration adjusted error 10
Code (used by the decoder) of the method used to estimate adjustment error 1_1
Date of last update of the tech data of the platform 14/06/2021 17:36:17
Configuration phases
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES SBE SBE41CP_V7.2.5 11564808
CTD_TEMP SBE SBE41CP_V7.2.5 13225
CTD_CNDC SBE SBE41CP_V7.2.5 13225
OPTODE_DOXY AANDERAA AANDERAA_OPTODE_4330 3501
RADIOMETER_DOWN_IRR380 SATLANTIC SATLANTIC_OCR504_ICSW 2145
RADIOMETER_DOWN_IRR412 SATLANTIC SATLANTIC_OCR504_ICSW 2145
RADIOMETER_DOWN_IRR490 SATLANTIC SATLANTIC_OCR504_ICSW 2145
RADIOMETER_PAR SATLANTIC SATLANTIC_OCR504_ICSW 2145
FLUOROMETER_CHLA WETLABS ECO_FLBBCD 6583
BACKSCATTERINGMETER_BBP700 WETLABS ECO_FLBBCD 6583
FLUOROMETER_CDOM WETLABS ECO_FLBBCD 6583
SPECTROPHOTOMETER_NITRATE SATLANTIC SUNA_V2 1487
AUX_SPECTROPHOTOMETER_NITRATE TRIOS OPUS_DS 72BC
Physical parameters
Name Units Accuracy Resolution
CTD_PRES decibar 2.4 1
CTD_TEMP degree_Celsius 0.002 0.001
CTD_CNDC psu 0.005 0.001
OPTODE_DOXY degree
OPTODE_DOXY degree
OPTODE_DOXY degree_Celsius
OPTODE_DOXY micromole/kg 8 1
OPTODE_DOXY millibar
RADIOMETER_DOWN_IRR380 count
RADIOMETER_DOWN_IRR412 count
RADIOMETER_DOWN_IRR490 count
RADIOMETER_PAR count
RADIOMETER_DOWN_IRR380 W/m^2/nm
RADIOMETER_DOWN_IRR412 W/m^2/nm
RADIOMETER_DOWN_IRR490 W/m^2/nm
RADIOMETER_PAR microMoleQuanta/m^2/sec
FLUOROMETER_CHLA count
BACKSCATTERINGMETER_BBP700 count
FLUOROMETER_CDOM count
FLUOROMETER_CHLA mg/m3 0.08 0.025
BACKSCATTERINGMETER_BBP700 m-1
FLUOROMETER_CDOM ppb
SPECTROPHOTOMETER_NITRATE degree_Celsius
SPECTROPHOTOMETER_NITRATE degree_Celsius
SPECTROPHOTOMETER_NITRATE percent
SPECTROPHOTOMETER_NITRATE count
SPECTROPHOTOMETER_NITRATE dimensionless
SPECTROPHOTOMETER_NITRATE count
SPECTROPHOTOMETER_NITRATE micromole/kg 2 0.01
SPECTROPHOTOMETER_NITRATE micromole/kg
AUX_SPECTROPHOTOMETER_NITRATE dimensionless
AUX_SPECTROPHOTOMETER_NITRATE count
AUX_SPECTROPHOTOMETER_NITRATE count
AUX_SPECTROPHOTOMETER_NITRATE count
AUX_SPECTROPHOTOMETER_NITRATE count
AUX_SPECTROPHOTOMETER_NITRATE count
AUX_SPECTROPHOTOMETER_NITRATE count
AUX_SPECTROPHOTOMETER_NITRATE count
Calibrations
Parameter Equation Coefficients Comment
PRES none
TEMP none
PSAL none
C1PHASE_DOXY
C2PHASE_DOXY
TEMP_DOXY
DOXY PhaseCoef0=-7.590000e-01, PhaseCoef1=1, PhaseCoef2=0, PhaseCoef3=0, c0=3.401880e-03, c1=1.478264e-04, c2=2.640204e-06, c3=1.775260e+02, c4=-2.391158e-01, c5=-4.121156e+01, c6=3.429421e+00
PPOX_DOXY
RAW_DOWNWELLING_IRRADIANCE380
RAW_DOWNWELLING_IRRADIANCE412
RAW_DOWNWELLING_IRRADIANCE490
RAW_DOWNWELLING_PAR
DOWN_IRRADIANCE380 A1_380=1.50758309914e-07, A0_380=2.14580984630e+09, lm_380=1.161e+00
DOWN_IRRADIANCE412 A1_412=2.06585732918e-07, A0_412=2.14700385270e+09, lm_412=1.368e+00
DOWN_IRRADIANCE490 A1_490=2.05279123860e-07, A0_490=2.14676606200e+08, lm_490=1.365e+00
DOWNWELLING_PAR A1_PAR=3.65507393731e-06, A0_PAR=2.14738598480e+09, lm_PAR=1.359e+00
FLUORESCENCE_CHLA
BETA_BACKSCATTERING700
FLUORESCENCE_CDOM
CHLA SCALE_CHLA=7.300e-03, DARK_CHLA=47
BBP700 SCALE_BACKSCATTERING700=9.120e-02, DARK_BACKSCATTERING700=50
CDOM SCALE_CDOM=1.914e-06, DARK_CDOM=47
TEMP_NITRATE
TEMP_SPECTROPHOTOMETER_NITRATE
HUMIDITY_NITRATE
UV_INTENSITY_DARK_NITRATE
FIT_ERROR_NITRATE
UV_INTENSITY_NITRATE
NITRATE PIXEL_START=36, PIXEL_END=126, PIXEL_FIT_START=36, PIXEL_FIT_END=
BISULFIDE
SPECTRUM_TYPE_NITRATE
AVERAGING_NITRATE
FLASH_COUNT_NITRATE
TEMP_NITRATE2
UV_INTENSITY_FULL_NITRATE
UV_INTENSITY_BINNED_NITRATE
UV_INTENSITY_DARK_NITRATE_AVG
UV_INTENSITY_DARK_NITRATE_SD
Technical parameters Details