Code 3901031
Name SOLO II Profiling Float SBE
Description Argo SIO
Project US ARGO PROJECT
Institution Scripps Institution of Oceanography, La Jolla (SIO)
Data Assembly Center AO : AOML
Activity Inactive
Status
Comment
First station date 23/09/2011 18:12:39
Last station date 01/11/2012 21:50:46
Float cycles 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 3901031
(C) Coriolis data centre - 2021.06.17
T/S Diagram
Section chart
Overlayed profiles
Waterfall profiles
Pressure chart
Configuration
Profiler LAUNCH DATETIME 23/09/2011 17:00:00
Profiler LAUNCH LATITUDE -10.998
Profiler LAUNCH LONGITUDE -105.006
Profiler PROBE CODE 854
Profiler EXPERIMENT ID US ARGO PROJECT
Platform activity flag I
The last valid station id of the platform 30542531
Data centre in charge of platform data processing AO
Positioning system GPS
Transmission identifier (ARGOS, ORBCOMM, etc.) n/a
The telecommunications system used IRIDIUM
The program identifier used by the transmission system n/a
The frequency of transmission from the float n/a
The repetition rate of transmission from the float -999
The rate of drift of the float clock 0
Model of the float SOLO2IR_SBE
The name of the manufacturer MRV
Instrument type 7010
Direction of the profiles A
Name of the principal investigator DEAN ROEMMICH
Quality on launch date, time and location 0
Quality on start date 9
Identifier of the deployment platform R/V Kaharoa
Identifier of the mission used to deploy the float unknown
Date (UTC) of the end of mission of the float 17/09/2013 12:42:48
Status of the end of mission of the float T
The number of times this cycle repeats 1
The time spent at the surface 0.5
Name of the project US ARGO PROJECT
The related loading id 61203614
Date of last update of the metadata of the platform 20/05/2021 22:42:20
Date of last update of the trajectory of the platform 02/04/2020 15:53:29
Name of the network related to the platform GROUP
Name of the network related to the platform MyOcean
Firmware version V01.00; SBE602 08Jun11
The manual version for the float V01.00
The serial number of the float 7010
A standard format number to describe the data format for each float 204010
The format number used by the DAC to describe the data format type for each float SOLO2IR_TS36
The type of battery packs in the float ELECTROCHEM Lithium 15 V
The configuration of battery packs in the float 3D Li
The type of controller board HC12 Rev:5.7
Extra features of the float (algorithms, compressee etc.) Buoyancy diagnostics are being placed in the auxiliary directory, as the reporting of such data has not been standardized.
The operating institution of the float SIO
Category of instrument FLOAT
Startup date of the float 23/09/2011 17:47:05
Platform type S2A
Configuration phases
Total time of a cycle : descent + parking + ascent + surface Preset duration of the down time (start of descent to start of ascent) Preset duration of the up time (start of ascent to start of descent) Pressure of subsurface drifts Deepest pressure sampled in the ascending profile
1000 2000
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES KISTLER KISTLER_2900PSIA 2073967 decibar
CTD_TEMP SBE SBE41CP_V3.0a 3783 degree_Celsius
CTD_CNDC SBE SBE41CP_V3.0a 3783 mS/cm
Physical parameters
Name Units Accuracy Resolution
CTD_PRES dbar 1.5% 0.01 dbar
CTD_TEMP degC (ITS-90) 0.002 degC 0.0001 degC
CTD_CNDC psu 0.002 psu 0.0001 psu
Calibrations
Parameter Equation Coefficients Comment
PRES y=thermistor output;t=PTHA0+PTHA1*y+PTHA2*y^2;x=pressure output-PTCA0-PTCA1*t-PTCA2*t^2;n=x*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2);pressure(psia)=PA0+PA1*n+PA2*n^2; PA0 = -8.025841E-01, PA1 = 1.311074E-01, PA2 = 1.182200E-08, PTCA0 = -2.468029E+02, PTCA1 = -9.614723E-01, PTCA2 = 3.144716E-02, PTCB0 = 1.076329E+02, PTCB1 = -8.392402E-03, PTCB2 = 0.000000E+00, PTHA0 = -9.979349E+01, PTHA1 = 4.401369E-02, PTHA2 = 2.94007 Pressure Calibration Date 20 05 2011
TEMP n=Instrument Output (counts); Temperature (ITS-90) = 1/{a0+a1[ln(n)]+a2[ln^2(n)]+a3[ln^3(n)]}-273.15 (oC); TA0 = 1.067810E-04, TA1 = 2.587821E-04, TA2 = -1.261902E-06, TA3 = 1.198801E-07, Temperature Calibration Date 01 06 2011
PSAL f=INST_FREQ*sqrt(1.0+wBOTC*t)/1000.0;Conductivity=(g+h*f^2+i*f^3+j*f^4)/(1+delta*t+epsilon*p) Siemens/meter;t=temperature[degC];p=pressure[dbar];delta=CTcor;epsilon=CPcor; G = -1.013472E+00, H = 1.521086E-01, I = -4.268534E-04, J = 5.499493E-05, CPCOR = -9.570001E-08, CTCOR = 3.250000E-06, WBOTC = -1.674470E-07, Conductivity Calibration Date 01 06 2011