Status
Comment
Login
Code 5903528
Name SOLO2IR_SBE_8012
Description Argo SIO
Project US ARGO PROJECT
Institution Scripps Institution of Oceanography, La Jolla (SIO)
Data Assembly Center AO : AOML
Activity Inactive
Status
Comment
First station date 02/04/2011 01:03:03
Last station date 14/10/2013 09:00:23
Float cycles 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 5903528
(C) Coriolis data centre - 2021.06.17
T/S Diagram
Section chart
Overlayed profiles
Waterfall profiles
Pressure chart
Configuration
Profiler LAUNCH DATETIME 02/04/2011 00:00:00
Profiler LAUNCH LATITUDE -0.015
Profiler LAUNCH LONGITUDE -152.242
Profiler PROBE CODE 853
Profiler EXPERIMENT ID US ARGO PROJECT
Platform activity flag I
The last valid station id of the platform 30863487
Data centre in charge of platform data processing AO
Positioning system GPS
Transmission identifier (ARGOS, ORBCOMM, etc.) n/a
The telecommunications system used IRIDIUM
The program identifier used by the transmission system n/a
The frequency of transmission from the float n/a
The repetition rate of transmission from the float -999
The rate of drift of the float clock 0
Model of the float SOLO2IR_SBE
The name of the manufacturer SIO_IDG
Instrument type 8012
Direction of the profiles A
Name of the principal investigator DEAN ROEMMICH
Quality on launch date, time and location 0
Quality on start date 9
Identifier of the deployment platform M/V Discovery
Identifier of the mission used to deploy the float unknown
Date (UTC) of the end of mission of the float 14/10/2013 09:22:21
Status of the end of mission of the float T
The number of times this cycle repeats 1
The time spent at the surface 0.5
Name of the project US ARGO PROJECT
The related loading id 61203676
Date of last update of the metadata of the platform 20/05/2021 22:42:44
Date of last update of the trajectory of the platform 24/01/2019 10:57:40
Name of the network related to the platform GROUP
Name of the network related to the platform MyOcean
List of parameters with real-time calibration information PSAL
Calibration equation for this parameter PSAL_ADJUSTED = a1 * PSAL + a0
Calibration coefficients for this equation a1=1, a0=0.0004
Comment applying to this parameter calibration Real-time salinity adjustment
Date of the calibration 20160719051857
Firmware version V01.00; SBE602 30Jan11
The manual version for the float V01.00
The serial number of the float 8012
A standard format number to describe the data format for each float 202010
The format number used by the DAC to describe the data format type for each float SOLO2IR_TS36
The type of battery packs in the float ELECTROCHEM Lithium 15 V
The configuration of battery packs in the float 2D Li
The type of controller board HC12 Rev:5.4
Extra features of the float (algorithms, compressee etc.) Buoyancy diagnostics are being placed in the auxiliary directory, as the reporting of such data has not been standardized.
The operating institution of the float SIO
Category of instrument FLOAT
Startup date of the float 02/04/2011 00:27:13
Platform type SOLO_II
Date of last update of the tech data of the platform 29/04/2021 09:03:20
Configuration phases
Total time of a cycle : descent + parking + ascent + surface Preset duration of the down time (start of descent to start of ascent) Preset duration of the up time (start of ascent to start of descent) Pressure of subsurface drifts Deepest pressure sampled in the ascending profile
1000 2000
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES DRUCK DRUCK_2900PSIA 3159509 decibar
CTD_TEMP SBE SBE41CP_V3.0a 3333 degree_Celsius
CTD_CNDC SBE SBE41CP_V3.0a 3333 mS/cm
Physical parameters
Name Units Accuracy Resolution
CTD_PRES dbar 1.5% 0.01 dbar
CTD_TEMP degC (ITS-90) 0.002 degC 0.0001 degC
CTD_CNDC psu 0.002 psu 0.0001 psu
Calibrations
Parameter Equation Coefficients Comment
PRES y=thermistor output;t=PTHA0+PTHA1*y+PTHA2*y^2;x=pressure output-PTCA0-PTCA1*t-PTCA2*t^2;n=x*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2);pressure(psia)=PA0+PA1*n+PA2*n^2; PA0 = 1.410724E+00, PA1 = 1.404112E-01, PA2 = -4.249889E-08, PTCA0 = 3.838098E+01, PTCA1 = 5.364419E-01, PTCA2 = -3.560504E-03, PTCB0 = 2.523575E+01, PTCB1 = 3.500000E-04, PTCB2 = 0.000000E+00, PTHA0 = -7.734777E+01, PTHA1 = 4.947155E-02, PTHA2 = -3.800500 Pressure Calibration Date 14 09 2010
TEMP n=Instrument Output (counts); Temperature (ITS-90) = 1/{a0+a1[ln(n)]+a2[ln^2(n)]+a3[ln^3(n)]}-273.15 (oC); TA0 = 3.381760E-05, TA1 = 2.705001E-04, TA2 = -2.128608E-06, TA3 = 1.432082E-07, Temperature Calibration Date 05 10 2010
PSAL f=INST_FREQ*sqrt(1.0+wBOTC*t)/1000.0;Conductivity=(g+h*f^2+i*f^3+j*f^4)/(1+delta*t+epsilon*p) Siemens/meter;t=temperature[degC];p=pressure[dbar];delta=CTcor;epsilon=CPcor; G = -1.043700E+00, H = 1.432311E-01, I = -3.377561E-04, J = 4.390579E-05, CPCOR = -9.570001E-08, CTCOR = 3.250000E-06, WBOTC = -1.232102E-07, Conductivity Calibration Date 05 10 2010
Technical parameters Details