Status
Comment
Login
Code 7900298
Name SOLO2IR_SBE_
Description Argo SIO
Project US ARGO PROJECT
Institution Scripps Institution of Oceanography, La Jolla (SIO)
Data Assembly Center AO : AOML
Activity Inactive
Status
Comment
First station date 18/05/2015 02:11:14
Last station date 12/04/2018 07:08:19
Float cycles 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
Float Argo trajectory for platform 7900298
(C) Coriolis data centre - 2021.06.17
T/S Diagram
Section chart
Overlayed profiles
Waterfall profiles
Configuration
Profiler LAUNCH DATETIME 18/05/2015 01:00:00
Profiler LAUNCH LATITUDE -61.357
Profiler LAUNCH LONGITUDE -142.066
Profiler PROBE CODE 853
Profiler EXPERIMENT ID US ARGO PROJECT
Platform activity flag I
The last valid station id of the platform 55344778
Data centre in charge of platform data processing AO
Positioning system GPS
Transmission identifier (ARGOS, ORBCOMM, etc.) n/a
The telecommunications system used IRIDIUM
The program identifier used by the transmission system n/a
The frequency of transmission from the float n/a
The repetition rate of transmission from the float -999
The rate of drift of the float clock 0
Model of the float SOLO2IR_SBE
The name of the manufacturer SIO_IDG
Instrument type 8358
Direction of the profiles A
Name of the principal investigator DEAN ROEMMICH
Quality on launch date, time and location 0
Quality on start date 9
Identifier of the deployment platform R/V Palmer
Identifier of the mission used to deploy the float NBP15-04
Date (UTC) of the end of mission of the float 12/04/2018 07:29:13
Status of the end of mission of the float T
The number of times this cycle repeats 1
The time spent at the surface 0.5
Name of the project US ARGO PROJECT
The related loading id 61200737
Date of last update of the metadata of the platform 20/05/2021 20:44:07
Date of last update of the trajectory of the platform 29/04/2021 13:31:37
Firmware version V02.00; SBE602 18Feb15
The manual version for the float V02.00
The serial number of the float 8358
A standard format number to describe the data format for each float 202020
The format number used by the DAC to describe the data format type for each float SOLO2IR_TS36
The type of battery packs in the float ELECTROCHEM Lithium 15 V
The configuration of battery packs in the float 3D Li
The type of controller board GG32 Rev:6.1
Extra features of the float (algorithms, compressee etc.) Buoyancy diagnostics are being placed in the auxiliary directory, as the reporting of such data has not been standardized.
The operating institution of the float SIO
Category of instrument FLOAT
Startup date of the float 18/05/2015 01:55:05
Platform type SOLO_II
Date of last update of the tech data of the platform 29/04/2021 14:30:41
Configuration phases
Total time of a cycle : descent + parking + ascent + surface Preset duration of the down time (start of descent to start of ascent) Preset duration of the up time (start of ascent to start of descent) Pressure of subsurface drifts Deepest pressure sampled in the ascending profile
1000 2000
Sensors
Name Maker Model Serial number Units Accuracy Resolution
CTD_PRES DRUCK DRUCK_2900PSIA 4037679 decibar
CTD_TEMP SBE SBE41CP_V3.0c 5798 degree_Celsius
CTD_CNDC SBE SBE41CP_V3.0c 5798 mS/cm
Physical parameters
Name Units Accuracy Resolution
CTD_PRES dbar 1.5% 0.01 dbar
CTD_TEMP degC (ITS-90) 0.002 degC 0.0001 degC
CTD_CNDC psu 0.002 psu 0.0001 psu
Calibrations
Parameter Equation Coefficients Comment
PRES y=thermistor output;t=PTHA0+PTHA1*y+PTHA2*y^2;x=pressure output-PTCA0-PTCA1*t-PTCA2*t^2;n=x*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2);pressure(psia)=PA0+PA1*n+PA2*n^2; PA0 = 5.450503E-02, PA1 = 1.401386E-01, PA2 = -3.637703E-08, PTCA0 = 8.935247E+00, PTCA1 = -6.819848E-02, PTCA2 = 4.067476E-03, PTCB0 = 2.517775E+01, PTCB1 = 5.500000E-04, PTCB2 = 0.000000E+00, PTHA0 = -8.021318E+01, PTHA1 = 5.346125E-02, PTHA2 = -1.008552 Pressure Calibration Date 14 04 2014
TEMP n=Instrument Output (counts); Temperature (ITS-90) = 1/{a0+a1[ln(n)]+a2[ln^2(n)]+a3[ln^3(n)]}-273.15 (oC); TA0 = 6.747769E-05, TA1 = 2.666903E-04, TA2 = -1.869731E-06, TA3 = 1.350024E-07, Temperature Calibration Date 18 04 2014
PSAL f=INST_FREQ*sqrt(1.0+wBOTC*t)/1000.0;Conductivity=(g+h*f^2+i*f^3+j*f^4)/(1+delta*t+epsilon*p) Siemens/meter;t=temperature[degC];p=pressure[dbar];delta=CTcor;epsilon=CPcor; G = -9.880854E-01, H = 1.427412E-01, I = -3.443707E-04, J = 4.565882E-05, CPCOR = -9.570001E-08, CTCOR = 3.250000E-06, WBOTC = -2.844378E-07, Conductivity Calibration Date 18 04 2014
Technical parameters Details